Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2025-27257

Quick assessment

Affected
GE Vernova N60 multilin
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

GE Vernova UR IED是美国GE Vernova公司的一系列保护继电器。 GE Vernova UR IED存在数据伪造问题漏洞,该漏洞源于数据真实性验证不足,可能导致安装修改后的固件。

CVSS 6.1 · Medium EPSS 0.18% · P7
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-27257

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
Insufficient Verification of Data Authenticity vulnerability in GE Vernova UR IED family devices allows an authenticated user to install a modified firmware. The firmware signature verification is enforced only on the client-side dedicated software Enervista UR Setup, allowing the integration check to be bypassed.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
对数据真实性的验证不充分
Source: CVE Program / CVE List V5
Vulnerability Title
GE Vernova UR IED 数据伪造问题漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
GE Vernova UR IED是美国GE Vernova公司的一系列保护继电器。 GE Vernova UR IED存在数据伪造问题漏洞,该漏洞源于数据真实性验证不足,可能导致安装修改后的固件。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
GE Vernova N60 multilin 7.0 ~ 8.60 -
GE Vernova B30 Multilin 7.0 ~ 8.60 -
GE Vernova B90 Multilin 7.0 ~ 8.60 -
GE Vernova C30 Multilin 7.0 ~ 8.60 -
GE Vernova C60 Multilin 7.0 ~ 8.60 -
GE Vernova C70 Multilin 7.0 ~ 8.60 -
GE Vernova C95 Multilin 7.0 ~ 8.60 -
GE Vernova D30 Multilin 7.0 ~ 8.60 -
GE Vernova D60 Multilin 7.0 ~ 8.60 -
GE Vernova F35 Multilin 7.0 ~ 8.60 -
GE Vernova F60 Multilin 7.0 ~ 8.60 -
GE Vernova G30 Multilin 7.0 ~ 8.60 -
GE Vernova G60 Multilin 7.0 ~ 8.60 -
GE Vernova L30 Multilin 7.0 ~ 8.60 -
GE Vernova L60 Multilin 7.0 ~ 8.60 -
GE Vernova L90 Multilin 7.0 ~ 8.60 -
GE Vernova M60 Multilin 7.0 ~ 8.60 -
GE Vernova T35 Multilin 7.0 ~ 8.60 -
GE Vernova T60 Multilin 7.0 ~ 8.60 -
GE Vernova M60 Multilin 7.0 ~ 8.60 -

II. Public POCs for CVE-2025-27257

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-27257

请登录查看更多情报信息。

Vendor Advisories for CVE-2025-27257 (1)

Vendor Pages for CVE-2025-27257 (1)

Same Patch Batch · GE Vernova · 2025-03-10 · 5 CVEs total

CVE-2025-27256 8.3 HIGH GE Vernova EnerVista UR 访问控制错误漏洞
CVE-2025-27255 8.0 HIGH GE Vernova EnerVista UR 信任管理问题漏洞
CVE-2025-27254 8.0 HIGH GE Vernova EnerVista UR 授权问题漏洞
CVE-2025-27253 6.1 MEDIUM GE Vernova UR IED 输入验证错误漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2025-27257

No comments yet