Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2025-40812

Quick assessment

Affected
Siemens Solid Edge SE2024
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Siemens Solid Edge SE2025和Siemens Solid Edge SE2024都是德国西门子(Siemens)公司的一款开发软件。 Siemens Solid Edge SE2025和Siemens Solid Edge SE2024存在缓冲区错误漏洞,该漏洞源于解析特制PRT文件时存在越界读取,可能导致应用程序崩溃或在当前进程环境中执行代码。以下版本受到影响:Solid Edge SE2024 V224.0 Update 14之前版本和Solid Edge SE2025 V225

CVSS 7.8 · High EPSS 0.14% · P3
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-40812

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
跨界内存读
Source: CVE Program / CVE List V5
Vulnerability Title
Siemens Solid Edge SE2025和Siemens Solid Edge SE2024 缓冲区错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens Solid Edge SE2025和Siemens Solid Edge SE2024都是德国西门子(Siemens)公司的一款开发软件。 Siemens Solid Edge SE2025和Siemens Solid Edge SE2024存在缓冲区错误漏洞,该漏洞源于解析特制PRT文件时存在越界读取,可能导致应用程序崩溃或在当前进程环境中执行代码。以下版本受到影响:Solid Edge SE2024 V224.0 Update 14之前版本和Solid Edge SE2025 V225
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Siemens Solid Edge SE2024 0 ~ V224.0 Update 14 -
Siemens Solid Edge SE2025 0 ~ V225.0 Update 6 -

II. Public POCs for CVE-2025-40812

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-40812

请登录查看更多情报信息。

Same Patch Batch · Siemens · 2025-10-14 · 12 CVEs total

CVE-2025-40765 9.8 CRITICAL Siemens TeleControl Server Basic 访问控制错误漏洞
CVE-2025-40771 9.8 CRITICAL Siemens SIMATIC CP Series 访问控制错误漏洞
CVE-2025-40755 8.8 HIGH Siemens SINEC NMS SQL注入漏洞
CVE-2025-40809 7.8 HIGH Siemens Solid Edge SE2025和Siemens Solid Edge SE2024 缓冲区错误漏洞
CVE-2025-40810 7.8 HIGH Siemens Solid Edge SE2025和Siemens Solid Edge SE2024 缓冲区错误漏洞
CVE-2025-40811 7.8 HIGH Siemens Solid Edge SE2025和Siemens Solid Edge SE2024 缓冲区错误漏洞
CVE-2011-20001 7.5 HIGH Siemens SIMATIC S7-1200 CPU V1 family和Siemens SIMATIC S7-1200 CPU V2 family 输入验证错误漏洞
CVE-2011-20002 7.4 HIGH Siemens SIMATIC S7-1200 CPU V1 family和Siemens SIMATIC S7-1200 CPU V2 family 安全漏洞
CVE-2025-40772 7.4 HIGH Siemens SiPass integrated 跨站脚本漏洞
CVE-2025-40774 4.4 MEDIUM Siemens SiPass Integrated 安全漏洞
CVE-2025-40773 3.5 LOW Siemens SiPass integrated 安全漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2025-40812

No comments yet


Leave a comment