CVE-2025-41665— Phoenix Contact: DoS of the PLC due to incorrect default permissions possible

Quick assessment

Affected
PHOENIX CONTACT AXC F 1152
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

PHOENIX CONTACT AXC F 1152等都是德国菲尼克斯电气(PHOENIX CONTACT)公司的一款控制器设备。 PHOENIX CONTACT多款产品存在安全漏洞,该漏洞源于配置文件默认权限不正确,可能导致低权限攻击者强制看门狗重启PLC。

CVSS 6.5 · Medium EPSS 0.31% · P24
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-41665

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Phoenix Contact: DoS of the PLC due to incorrect default permissions possible
Source: CVE Program / CVE List V5
Vulnerability Description
An low privileged remote attacker can enforce the watchdog of the affected devices to reboot the PLC due to incorrect default permissions of a config file.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
缺省权限不正确
Source: CVE Program / CVE List V5
Vulnerability Title
PHOENIX CONTACT多款产品 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
PHOENIX CONTACT AXC F 1152等都是德国菲尼克斯电气(PHOENIX CONTACT)公司的一款控制器设备。 PHOENIX CONTACT多款产品存在安全漏洞,该漏洞源于配置文件默认权限不正确,可能导致低权限攻击者强制看门狗重启PLC。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
PHOENIX CONTACT AXC F 1152 0 ~ 2025.0.2 -
PHOENIX CONTACT AXC F 2152 0 ~ 2025.0.2 -
PHOENIX CONTACT AXC F 3152 0 ~ 2025.0.2 -
PHOENIX CONTACT BPC 9102S 0 ~ 2025.0.2 -
PHOENIX CONTACT RFC 4072S 0 ~ 2025.0.2 -

II. Public POCs for CVE-2025-41665

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-41665

登录查看更多情报信息。

Vendor Advisories for CVE-2025-41665 (1)

Same Patch Batch · PHOENIX CONTACT · 2025-07-08 · 13 CVEs total

CVE-2025-25270 9.8 CRITICAL Remote Code Execution via Unauthenticated Configuration Manipulation
CVE-2025-41666 8.8 HIGH Phoenix Contact: File access due to the replacement of a critical file used by the watchdo
CVE-2025-41667 8.8 HIGH Phoenix Contact: File access due to the replacement of a critical file used by the arp-pre
CVE-2025-41668 8.8 HIGH Phoenix Contact: File access due to the replacement of a critical file used by the service
CVE-2025-25271 8.8 HIGH OCPP Backend Configuration via Insecure Defaults
CVE-2025-25268 8.8 HIGH Unauthenticated Configuration Access via Exposed API Endpoint
CVE-2025-25269 8.4 HIGH Local Privilege Escalation via Unauthenticated Command Injection
CVE-2025-24003 8.2 HIGH MQTT OOB Write Vulnerability in EichrechtAgents of German EV Charging Stations
CVE-2025-24005 7.8 HIGH Local Privilege Escalation via Vulnerable SSH Script
CVE-2025-24006 7.8 HIGH Privilege Escalation via Insecure SSH Permissions
CVE-2025-24002 5.3 MEDIUM MQTT DoS Vulnerability in German EV Charging Stations
CVE-2025-24004 5.2 MEDIUM USB-C Buffer Overflow via Display Interface in EV Charging Stations

IV. Related Vulnerabilities

V. Comments for CVE-2025-41665

No comments yet


Leave a comment