Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2025-41746— Reflected XSS vulnerability in pxc_portSecCfg.php

Quick assessment

Affected
Phoenix Contact FL SWITCH 2005
Exploitation
High exploitation probability; assess promptly
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

PHOENIX CONTACT FL SWITCH是德国菲尼克斯电气(PHOENIX CONTACT)公司的一款工业级以太网交换机。 PHOENIX CONTACT FL SWITCH 3.50之前版本存在跨站脚本漏洞,该漏洞源于跨站脚本攻击,可能导致设备配置参数被修改。

CVSS 7.1 · High EPSS 9.77% · P95

Possible ATT&CK Techniques 1 AI

T1189 · Drive-by Compromise
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-41746

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Reflected XSS vulnerability in pxc_portSecCfg.php
Source: CVE Program / CVE List V5
Vulnerability Description
An XSS vulnerability in pxc_portSecCfg.php can be used by an unauthenticated remote attacker to trick an authenticated user to send a manipulated POST request to the device in order to change parameters available via web based management (WBM). The vulnerability does not provide access to system-level resources such as operating system internals or privileged functions. Access is limited to device configuration parameters that are available in the context of the web application. The session cookie is secured by the httpOnly Flag. Therefore an attacker is not able to take over the session of an authenticated user.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L
Source: CVE Program / CVE List V5
Vulnerability Type
在Web页面生成时对输入的转义处理不恰当(跨站脚本)
Source: CVE Program / CVE List V5
Vulnerability Title
PHOENIX CONTACT FL SWITCH 跨站脚本漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
PHOENIX CONTACT FL SWITCH是德国菲尼克斯电气(PHOENIX CONTACT)公司的一款工业级以太网交换机。 PHOENIX CONTACT FL SWITCH 3.50之前版本存在跨站脚本漏洞,该漏洞源于跨站脚本攻击,可能导致设备配置参数被修改。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Phoenix Contact FL SWITCH 2005 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2008 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2016 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2105 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2108 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2116 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2204-2TC-2SFX 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2205 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2206-2FX 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2206-2FX SM 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2206-2FX SM ST 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2206-2FX ST 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2206-2SFX 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2206-2SFX PN 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2206C-2FX 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2207-FX 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2207-FX SM 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2208 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2208 PN 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2208C 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2212-2TC-2SFX 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2214-2FX 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2214-2FX SM 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2214-2SFX 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2214-2SFX PN 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2216 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2216 PN 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2304-2GC-2SFP 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2306-2SFP 0.0.0 ~ 3.50 -
Phoenix Contact FL SWITCH 2306-2SFP PN 0.0.0 ~ 3.50 -

II. Public POCs for CVE-2025-41746

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-41746

登录查看更多情报信息。

Other References for CVE-2025-41746 (1)

Same Patch Batch · Phoenix Contact · 2025-12-09 · 14 CVEs total

CVE-2025-41695 7.1 HIGH Reflected XSS vulnerability in dyn_conn.php
CVE-2025-41749 7.1 HIGH Reflected XSS vulnerability in port_util.php
CVE-2025-41751 7.1 HIGH Reflected XSS vulnerability in pxc_portCntr.php
CVE-2025-41745 7.1 HIGH Reflected XSS vulnerability in pxc_portCntr2.php
CVE-2025-41750 7.1 HIGH Reflected XSS vulnerability in pxc_PortCfg.php
CVE-2025-41747 7.1 HIGH Reflected XSS vulnerability in pxc_vlanIntfCfg.php
CVE-2025-41748 7.1 HIGH Reflected XSS vulnerability in pxc_Dot1xCfg.php
CVE-2025-41752 7.1 HIGH Reflected XSS vulnerability in pxc_portSfp.php
CVE-2025-41692 6.8 MEDIUM Weak/Predictable root Password
CVE-2025-41697 6.8 MEDIUM Shell access to UART Console
CVE-2025-41694 6.5 MEDIUM Authenticated Denial-of-Service via Webshell
CVE-2025-41696 4.6 MEDIUM Hardcoded User Password
CVE-2025-41693 4.3 MEDIUM Authenticated Denial-of-Service via SSH

IV. Related Vulnerabilities

V. Comments for CVE-2025-41746