Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2025-5862— Tenda AC7 setPptpUserList formSetPPTPUserList buffer overflow

Quick assessment

Affected
Tenda AC7
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda AC7是中国腾达(Tenda)公司的一款无线路由器。 Tenda AC7 15.03.06.44版本存在安全漏洞,该漏洞源于文件/goform/setPptpUserList中参数list的操作导致缓冲区溢出。

CVSS 8.8 · High EPSS 0.99% · P61

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-5862

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda AC7 setPptpUserList formSetPPTPUserList buffer overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
未进行输入大小检查的缓冲区拷贝(传统缓冲区溢出)
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda AC7 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda AC7是中国腾达(Tenda)公司的一款无线路由器。 Tenda AC7 15.03.06.44版本存在安全漏洞,该漏洞源于文件/goform/setPptpUserList中参数list的操作导致缓冲区溢出。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda AC7 15.03.06.44 -

II. Public POCs for CVE-2025-5862

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-5862

请登录查看更多情报信息。

Same Patch Batch · Tenda · 2025-06-09 · 9 CVEs total

CVE-2025-5863 8.8 HIGH Tenda AC5 SetRebootTimer formSetRebootTimer stack-based overflow
CVE-2025-5861 8.8 HIGH Tenda AC7 AdvSetLanip fromadvsetlanip buffer overflow
CVE-2025-5855 8.8 HIGH Tenda AC6 SetRebootTimer formSetRebootTimer stack-based overflow
CVE-2025-5854 8.8 HIGH Tenda AC6 AdvSetLanip fromadvsetlanip buffer overflow
CVE-2025-5853 8.8 HIGH Tenda AC6 SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow
CVE-2025-5852 8.8 HIGH Tenda AC6 setPptpUserList formSetPPTPUserList buffer overflow
CVE-2025-5900 4.3 MEDIUM Tenda AC9 cross-site request forgery
CVE-2025-5864 3.7 LOW Tenda TDSEE App Password Reset Confirmation Code ConfirmSmsCode excessive authentication

IV. Related Vulnerabilities

V. Comments for CVE-2025-5862

No comments yet


Leave a comment