Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2025-64119— Nuvation Energy BMS Client-side Authentication

Quick assessment

Affected
Nuvation Energy Battery Management System
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Nuvation Energy Battery Management System是美国Nuvation Energy公司的一个电池管理系统。 Nuvation Energy Battery Management System 2.3.9及之前版本存在安全漏洞,该漏洞源于允许身份验证绕过。

AI Predicted 9.1 Difficulty: Moderate EPSS 0.46% · P38
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-64119

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Nuvation Energy BMS Client-side Authentication
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability in Nuvation Battery Management System allows Authentication Bypass.This issue affects Battery Management System: through 2.3.9.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/S:P/AU:Y
Source: CVE Program / CVE List V5
Vulnerability Type
使用客户端的认证机制
Source: CVE Program / CVE List V5
Vulnerability Title
Nuvation Energy Battery Management System 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Nuvation Energy Battery Management System是美国Nuvation Energy公司的一个电池管理系统。 Nuvation Energy Battery Management System 2.3.9及之前版本存在安全漏洞,该漏洞源于允许身份验证绕过。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Nuvation Energy Battery Management System 0 ~ 2.3.9 -

II. Public POCs for CVE-2025-64119

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-64119

请登录查看更多情报信息。

Vendor Advisories for CVE-2025-64119 (1)

Same Patch Batch · Nuvation Energy · 2026-01-02 · 5 CVEs total

CVE-2025-64123 Nuvation Energy Multi-Stack Controller Proxy service allows arbitrary BMS access
CVE-2025-64122 Nuvation Energy Multi-Stack Controller Private Key Stored on Device
CVE-2025-64120 Nuvation Energy Multi-Stack Controller OS Command Injection
CVE-2025-64121 Nuvation Energy Multi-Stack Controller Authentication Bypass