Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2025-7598— Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow

Quick assessment

Affected
Tenda AX1803
Exploitation
Public or AI PoC available; prioritize validation
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda AX1803是中国腾达(Tenda)公司的一款双频千兆WIFI6路由器。 Tenda AX1803 1.0.0.1版本存在安全漏洞,该漏洞源于文件/goform/setWifiFilterCfg中函数formSetWifiMacFilterCfg对参数deviceList的错误操作导致栈缓冲区溢出。

CVSS 8.8 · High EPSS 0.82% · P56
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-7598

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda AX1803 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda AX1803是中国腾达(Tenda)公司的一款双频千兆WIFI6路由器。 Tenda AX1803 1.0.0.1版本存在安全漏洞,该漏洞源于文件/goform/setWifiFilterCfg中函数formSetWifiMacFilterCfg对参数deviceList的错误操作导致栈缓冲区溢出。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda AX1803 1.0.0.1 -

II. Public POCs for CVE-2025-7598

# POC Description Source Link Shenlong Link
AI-Generated POC Premium
Qwen3.6-35B-A3B · 8479 chars
Pro+ exclusive includes:
Vulnerability reproduction recording (real sandbox build + trigger, exclusive)
In-depth vulnerability mechanism
Trigger conditions & impact
Full executable POC code
Exploit chain & mitigation
POC zip download
100+ AI POC generations per month

III. Intelligence Information for CVE-2025-7598

请登录查看更多情报信息。

Same Patch Batch · Tenda · 2025-07-14 · 4 CVEs total

CVE-2025-7597 8.8 HIGH Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow
CVE-2025-7596 8.8 HIGH Tenda FH1205 WifiExtraSet formWifiExtraSet stack-based overflow
CVE-2025-7586 8.8 HIGH Tenda AC500 setWtpData formSetAPCfg stack-based overflow

IV. Related Vulnerabilities

V. Comments for CVE-2025-7598

No comments yet


Leave a comment