CVE-2026-0857

Quick assessment

Affected
Mesalvo Meona Client
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Mesalvo Meona Client Launcher Component和Mesalvo Meona Server Component都是Mesalvo公司的产品。Mesalvo Meona Client Launcher Component是一个面向医疗信息系统客户端启动与应用接入的组件。Mesalvo Meona Server Component是一个面向医院临床工作流与患者数据管理的服务端组件。 Mesalvo Meona Client Launcher Component 19.06.202

CVSS 4.4 · Medium EPSS 0.10% · P1

Possible ATT&CK Techniques 1 AI

T1552 · Unsecured Credentials

Affected Version Matrix 6

VendorProduct Version RangeStatus
Mesalvo Meona Client 2024.10 affected
2025.04< 2025.04.24 affected
2026.03< 2026.03.02 affected
Mesalvo Meona Server 2024.10 affected
2025.04< 2025.04.24 affected
2026.03< 2026.03.02 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-0857

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
Use of a Password Hash With Insufficient Computational Effort in Mesalvo MEONA (MEONA Server and MEONA Client) for user accounts whose password was last set under a version before MEONA 2024.10. MEONA versions before 2024.10 protected stored passwords with SHA-1 (versions from October 2015) or stored them without protection (earlier versions). Since MEONA 2024.10 (June 2024) Argon2 is the default method and every password that is set or changed is stored with Argon2; passwords last set under an earlier version keep the earlier method until they are changed. An administrator could in addition select the storage method per account. A MEONA super administrator can read the stored value of such accounts in the user administration of the MEONA Client or export it through administrative database functions. Only accounts managed locally in MEONA are affected; accounts authenticated through the operating hospital's directory service (Active Directory / Entra ID) have no password stored in MEONA. In typical installations end users authenticate through the directory service and local accounts are limited to emergency and technical accounts. Exploitation requires super administrator permissions in MEONA (or direct access to the MEONA database) from within the operating hospital's network; MEONA is operated exclusively within closed hospital networks without exposure to the public Internet, and where a hospital permits remote access to that network at all, it is only through the hospital's own remote-access infrastructure (e.g. VPN) under the hospital's control. Installations in which every password has been set or changed under MEONA 2024.10 or later are not affected. Mesalvo is not aware of any exploitation outside the reported security test. This issue affects MEONA Server and MEONA Client in versions 2024.10, 2025.04 and 2026.03 (for accounts with passwords last set under earlier versions). MEONA 2025.04.24 and 2026.03.02 (planned Q4 2026) remove the legacy storage methods, require every affected account to set a new Argon2-protected password at next logon, and no longer display stored credential values in the user administration. See Mesalvo Security Advisory MSA-2026-002.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
Source: CVE Program / CVE List V5
Vulnerability Type
使用具有不充分计算复杂性的口令哈希
Source: CVE Program / CVE List V5
Vulnerability Title
Mesalvo Meona Client Launcher Component和Mesalvo Meona Server Component 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Mesalvo Meona Client Launcher Component和Mesalvo Meona Server Component都是Mesalvo公司的产品。Mesalvo Meona Client Launcher Component是一个面向医疗信息系统客户端启动与应用接入的组件。Mesalvo Meona Server Component是一个面向医院临床工作流与患者数据管理的服务端组件。 Mesalvo Meona Client Launcher Component 19.06.202
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Mesalvo Meona Client 2024.10 -
Mesalvo Meona Server 2024.10 -

II. Public POCs for CVE-2026-0857

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-0857

请登录查看更多情报信息。

Security Blog Posts for CVE-2026-0857 (1)

Other References for CVE-2026-0857 (1)

Same Patch Batch · Mesalvo · 2026-05-20 · 4 CVEs total

CVE-2026-22314 7.9 HIGH Mesalvo Meona Client Launcher Component和Mesalvo Meona Server Component 代码注入漏洞