Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-102675— Electron: File and HTTP protocol handlers allow cross-origin reads without corsEnabled

Quick assessment

Affected
electron electron
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to 41.10.6, 42.9.2, 43.4.1, and 44.0.0-beta.5, responses served through protocol.registerFileProtocol or protocol.registerHttpProtocol for a custom sc

CVSS 7.4 · High
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-102675

Vulnerability Information

Shenlong is analyzing...


Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Electron: File and HTTP protocol handlers allow cross-origin reads without corsEnabled
Source: CVE Program / CVE List V5
Vulnerability Description
Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to 41.10.6, 42.9.2, 43.4.1, and 44.0.0-beta.5, responses served through protocol.registerFileProtocol or protocol.registerHttpProtocol for a custom scheme registered with supportFetchAPI enabled but corsEnabled disabled could remain script-readable across origins. This residual issue completes the remediation for CVE-2026-70604. Applications are affected only when they expose such a scheme and load untrusted content in the same session. Schemes intentionally registered with corsEnabled enabled remain cross-origin readable by design. This issue is fixed in versions 41.10.6, 42.9.2, 43.4.1, and 44.0.0-beta.5.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N
Source: CVE Program / CVE List V5
Vulnerability Type
源验证错误
Source: CVE Program / CVE List V5

Affected Products

Vendor Product Affected Versions CPE Subscribe
electron electron < 41.10.6 -

II. Public POCs for CVE-2026-102675

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-102675

请登录查看更多情报信息。

Other References for CVE-2026-102675 (9)

Same Patch Batch · electron · 2026-09-29 · 5 CVEs total

CVE-2026-102676 8.3 HIGH Electron: <webview> can enable Node.js integration in Web Workers despite embedder restric
CVE-2026-102673 8.2 HIGH Electron drops inherited HTML sandbox restrictions for popups opened through OpenURLFromTa
CVE-2026-102674 8.2 HIGH Electron: Windows opened from a sandboxed top-level document do not inherit its sandbox re
CVE-2026-102677 7.8 HIGH Electron: Sandboxed preload code cache can be poisoned by a compromised renderer

IV. Related Vulnerabilities