Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-102677— Electron: Sandboxed preload code cache can be poisoned by a compromised renderer

Quick assessment

Affected
electron electron
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. From 42.3.3 until 42.10.0, 43.5.0, and 44.0.0-beta.6, Electron's sandboxed preload code cache did not verify that a cached entry matched the preload it was

CVSS 7.8 · High
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-102677

Vulnerability Information

Shenlong is analyzing...


Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Electron: Sandboxed preload code cache can be poisoned by a compromised renderer
Source: CVE Program / CVE List V5
Vulnerability Description
Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. From 42.3.3 until 42.10.0, 43.5.0, and 44.0.0-beta.6, Electron's sandboxed preload code cache did not verify that a cached entry matched the preload it was served for. A compromised renderer could write attacker-controlled cache data and cause Electron to reuse it for a later load, executing the renderer's code in the more privileged preload context. The issue affects applications that load untrusted content. This issue is fixed in versions 42.10.0, 43.5.0, and 44.0.0-beta.6.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
输入验证不恰当
Source: CVE Program / CVE List V5

Affected Products

Vendor Product Affected Versions CPE Subscribe
electron electron >= 42.3.3, < 42.10.0 -

II. Public POCs for CVE-2026-102677

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-102677

请登录查看更多情报信息。

Other References for CVE-2026-102677 (8)

Same Patch Batch · electron · 2026-09-29 · 5 CVEs total

CVE-2026-102676 8.3 HIGH Electron: <webview> can enable Node.js integration in Web Workers despite embedder restric
CVE-2026-102673 8.2 HIGH Electron drops inherited HTML sandbox restrictions for popups opened through OpenURLFromTa
CVE-2026-102674 8.2 HIGH Electron: Windows opened from a sandboxed top-level document do not inherit its sandbox re
CVE-2026-102675 7.4 HIGH Electron: File and HTTP protocol handlers allow cross-origin reads without corsEnabled

IV. Related Vulnerabilities

V. Comments for CVE-2026-102677

No comments yet