Netgate pfSense CE 2.9.0 及更早版本存在一个配置注入漏洞,允许已认证的 WebGUI 用户通过提交未转义的 RADIUS 共享密钥来注入 mpd5 命令。具有 L2TP 或 PPPoE 服务器编辑权限的攻击者可以在 vpn_l2tp.php 或 services_pppoe_edit.php 中 POST 包含引号和换行符的密钥,从而附加一个在会话启动时以 root 权限执行的 up-script。
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| Netgate | pfSense CE | ≤ 2.9.0 |
affected |
Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.
| Vendor | Product | Affected Versions | CPE | Subscribe |
|---|---|---|---|---|
| Netgate | pfSense CE | 0 ~ 2.9.0 | - |
|
| # | POC Description | Source Link | Shenlong Link |
|---|
No public POC found.
Login to generate AI POC| CVE-2026-110908 | 8.8 HIGH | pfSense FRR 2.0.2_1命令注入漏洞 |
| CVE-2026-111224 | 7.5 HIGH | Netgate pfSense CE through 2.9.0 OS Command Injection via openvpn.connect_async.sh |
| CVE-2026-111223 | 7.2 HIGH | Netgate pfSense CE 2.7.0 through 2.9.0 Command Injection via IPsec Mobile Login Banner |
| CVE-2026-111218 | 7.2 HIGH | Netgate pfSense CE 2.7.0 through 2.9.0 OS Command Injection via Traffic Shaper Limiters |
| CVE-2026-111215 | 7.2 HIGH | Netgate pfSense CE through 2.9.0 OS Command Injection via Wireless Parent Interface |
| CVE-2026-111217 | 7.2 HIGH | Netgate pfSense CE through 2.9.0 OS Command Injection via CARP VHID |
| CVE-2026-111214 | 7.2 HIGH | Netgate pfSense CE 2.7.0 through 2.9.0 OS Command Injection via interfaces_qinq_edit.php |
| CVE-2026-111216 | 7.2 HIGH | Netgate pfSense CE through 2.9.0 OS Command Injection via Gateway Monitor IP |
| CVE-2026-111226 | 7.2 HIGH | Netgate pfSense CE 2.4.5 through 2.9.0 OS Command Injection via system_advanced_admin.php |
| CVE-2026-111231 | 7.2 HIGH | Netgate pfSense CE through 2.9.0 Authorization Bypass via config_restore() and config_inst |
| CVE-2026-111220 | 7.2 HIGH | Netgate pfSense CE through 2.9.0 Crontab Injection via PPP Periodic Reset ptpid |
| CVE-2026-111229 | 7.2 HIGH | Netgate pfSense CE 2.7.0 through 2.9.0 Command Injection via Captive Portal HA Sync |
| CVE-2026-111222 | 6.6 MEDIUM | Netgate pfSense CE through 2.9.0 php.ini Injection via Timezone Setting |
| CVE-2026-111219 | 6.6 MEDIUM | Netgate pfSense CE through 2.9.0 Command Injection via PPPoE Server Username |
| CVE-2026-111228 | 5.5 MEDIUM | Netgate pfSense CE 2.7.1 through 2.9.0 CRLF Injection via services_unbound_advanced.php |
| CVE-2026-111227 | 5.5 MEDIUM | Netgate pfSense CE through 2.9.0 CRLF Injection via services_unbound_acls.php |
| CVE-2026-111225 | 5.0 MEDIUM | Netgate pfSense CE 2.5.0 through 2.9.0 OS Command Injection via openvpn.learn-address.sh |
| CVE-2026-111230 | 4.9 MEDIUM | Netgate pfSense CE through 2.9.0 Local File Read via Dynamic DNS Update URL |
| CVE-2026-111232 | 4.8 MEDIUM | Netgate pfSense CE 2.3.0 through 2.9.0 Stored XSS via Separator Color |
| CVE-2026-111233 | 4.7 MEDIUM | Netgate pfSense CE 2.7.1 through 2.9.0 Reflected XSS via firewall_rules.php |
No comments yet