Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-114124— Electron: Off-screen rendering on macOS trusts GPU-supplied frame geometry

Quick assessment

Affected
electron electron
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Electron 是一个用于使用 JavaScript、HTML 和 CSS 开发跨平台桌面应用程序的框架。在版本 42.11.6、43.7.3、44.4.3 和 45.0.0-alpha.9 之前,主进程未对 macOS 离屏渲染场景中来自 GPU 进程的帧数据进行完整验证。若攻击者已在 GPU 进程中单独获得代码执行权限,则可提供不一致的帧几何信息,导致主进程在生成绘制事件图像时读取越界内存,从而泄露内存内容或造成应用程序崩溃。该问题已在版本 42.11.6、43.7.3、44.4.3 和 45.0.0-alp

CVSS 3.9 · Low

Affected Version Matrix 4

VendorProduct Version RangeStatus
electron electron < 42.11.6 affected
>= 43.0.0-alpha.1, < 43.7.3 affected
>= 44.0.0-alpha.1, < 44.4.3 affected
>= 45.0.0-alpha.1, < 45.0.0-alpha.9 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-114124

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Electron: Off-screen rendering on macOS trusts GPU-supplied frame geometry
Source: CVE Program / CVE List V5
Vulnerability Description
Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to versions 42.11.6, 43.7.3, 44.4.3, and 45.0.0-alpha.9, frame data received from the GPU process for macOS offscreen rendering was not fully validated by the main process. An attacker who had separately gained code execution in the GPU process could provide inconsistent frame geometry and cause the main process to read out-of-bounds memory while producing paint event images, disclosing memory or crashing the application. This issue is fixed in versions 42.11.6, 43.7.3, 44.4.3, and 45.0.0-alpha.9.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:L/I:N/A:L
Source: CVE Program / CVE List V5
Vulnerability Type
跨界内存读
Source: CVE Program / CVE List V5

Affected Products

Vendor Product Affected Versions CPE Subscribe
electron electron < 42.11.6 -

II. Public POCs for CVE-2026-114124

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-114124

请登录查看更多情报信息。

Patches & Fixes for CVE-2026-114124 (9)

Vendor Advisories for CVE-2026-114124 (1)

Vendor Pages for CVE-2026-114124 (4)

Same Patch Batch · electron · 2026-10-21 · 7 CVEs total

CVE-2026-114121 5.4 MEDIUM Electron: openExternal permission requests can be attributed to the wrong origin
CVE-2026-113800 5.4 MEDIUM Electron: HID and USB permission checks can be attributed to the wrong origin
CVE-2026-113798 5.4 MEDIUM Electron: Pointer lock permission requests can be attributed to the wrong frame
CVE-2026-113796 4.2 MEDIUM Electron: SameSite cookie restrictions are not applied to windows opened from links
CVE-2026-114122 3.9 LOW Electron: Frame subscription trusts GPU-supplied frame geometry
CVE-2026-113797 3.1 LOW Electron: Extension tabs.query returns tab URLs and titles without the tabs permission

IV. Related Vulnerabilities

V. Comments for CVE-2026-114124

No comments yet


Leave a comment