Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-116508— TOTOLINK A950RG Device-Information CGI infostat.cgi sub_402340 stack-based overflow

Quick assessment

Affected
TOTOLINK A950RG
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

在 TOTOLINK A950RG 固件版本 4.1.2cu.5268_B20221104 中发现一处安全漏洞。该漏洞影响设备信息 CGI 组件中 infostat.cgi 文件的 sub_402340 函数。攻击者通过操纵 CONTENT_LENGTH 参数,可触发基于栈的缓冲区溢出。此漏洞可被远程利用,且相关利用代码(Exploit)已公开,可能被用于发起攻击。

CVSS 10.0 · Critical
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-116508

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
TOTOLINK A950RG Device-Information CGI infostat.cgi sub_402340 stack-based overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A security flaw has been discovered in TOTOLINK A950RG 4.1.2cu.5268_B20221104. Affected by this issue is the function sub_402340 of the file infostat.cgi of the component Device-Information CGI. Performing a manipulation of the argument CONTENT_LENGTH results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5

Affected Products

Vendor Product Affected Versions CPE Subscribe
TOTOLINK A950RG 4.1.2cu.5268_B20221104 cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*

II. Public POCs for CVE-2026-116508

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-116508

请登录查看更多情报信息。

Other References for CVE-2026-116508 (4)

Same Patch Batch · TOTOLINK · 2026-10-26 · 5 CVEs total

CVE-2026-116506 9.9 CRITICAL TOTOLINK A950RG firewall.so apmib_set command injection
CVE-2026-116504 9.9 CRITICAL TOTOLINK A950RG Cloud Upgrade upgrade.so setCloudUpgradeFW command injection
CVE-2026-116505 9.1 CRITICAL TOTOLINK A950RG device-information udhcpd.leases getDeviceInfo command injection
CVE-2026-116507 5.3 MEDIUM TOTOLINK A950RG global.so getLanguageCfg information disclosure