Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-118468— AIS XML parsers allow external entity resolution

Quick assessment

Affected
CompuGroup Medical Infantia
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

XML 解析器在启用外部实体解析的情况下,处理由攻击者控制的更新清单或网络响应,可能导致 XML 外部实体(XXE)攻击。

CVSS 7.2 · High

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-118468

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
AIS XML parsers allow external entity resolution
Source: CVE Program / CVE List V5
Vulnerability Description
XML parsers process attacker-influenced update manifests or network responses with external entity resolution enabled, potentially allowing XML External Entity (XXE) attacks.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U
Source: CVE Program / CVE List V5
Vulnerability Type
XML外部实体引用的不恰当限制(XXE)
Source: CVE Program / CVE List V5

Affected Products

Vendor Product Affected Versions CPE Subscribe
CompuGroup Medical Infantia 0 ~ 6.01.1 -
CompuGroup Medical Profim 0 ~ 6.01.1 -
CompuGroup Medical Phronesis 0 ~ 4.51.0 -
CompuGroup Medical Venere 0 ~ 8.33.2 -

II. Public POCs for CVE-2026-118468

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-118468

请登录查看更多情报信息。

Other References for CVE-2026-118468 (2)

Same Patch Batch · CompuGroup Medical · 2026-11-09 · 16 CVEs total

CVE-2026-118462 9.2 CRITICAL AIS update mechanism executes unverified code
CVE-2026-112172 8.1 HIGH Unauthenticated SQL Execution in XDent/XMedical Synchronization Infrastructure
CVE-2026-118458 8.1 HIGH AIS shared test login provider contains fixed administrative credentials
CVE-2026-118461 8.0 HIGH AIS PersonnelService client performs unauthenticated doctor-specific operations
CVE-2026-118460 8.0 HIGH AIS embedded private keys enable practitioner impersonation
CVE-2026-118791 7.2 HIGH Insecure software update mechanism
CVE-2026-118790 7.2 HIGH Multiple Hardcoded Credentials
CVE-2026-118459 6.3 MEDIUM AIS PasswordSOS permits authentication without legitimate credentials
CVE-2026-118792 6.1 MEDIUM Default ODBC credentials
CVE-2026-118450 5.9 MEDIUM Venere loads replaceable unsigned components from a writable installation location
CVE-2026-118795 5.9 MEDIUM AIS stores authorization state in locally modifiable databases
CVE-2026-118464 5.8 MEDIUM AIS shared cryptographic services use fixed cryptographic secrets
CVE-2026-118465 5.8 MEDIUM AIS products use vendor-wide hard-coded database credentials
CVE-2026-118798 4.4 MEDIUM Multiple sensitive authentication data exposed
CVE-2026-118467 4.3 MEDIUM AIS products expose clinical and personal data via logs and telemetry