Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-121599— TOTOLINK A950RG Multi-SSID Configuration cstecgi.cgi delWiFiMultipleConfig stack-based overflow

Quick assessment

Affected
TOTOLINK A950RG
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

在 TOTOLINK A950RG 固件版本 4.1.2cu.5268_B20221104 中发现一个安全漏洞。该漏洞影响位于 文件中、属于“多 SSID 配置”组件的 和 函数。通过对参数 或 进行恶意篡改,可引发基于栈的缓冲区溢出。攻击者可在远程发起此攻击。目前该漏洞的利用代码(Exploit)已公开,存在被实际利用的风险。

CVSS 9.9 · Critical

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-121599

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
TOTOLINK A950RG Multi-SSID Configuration cstecgi.cgi delWiFiMultipleConfig stack-based overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability was detected in TOTOLINK A950RG 4.1.2cu.5268_B20221104. Affected is the function setWiFiMultipleConfig/delWiFiMultipleConfig of the file /cgi-bin/cstecgi.cgi of the component Multi-SSID Configuration. The manipulation of the argument wepkey2/wepkey3 results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5

Affected Products

Vendor Product Affected Versions CPE Subscribe
TOTOLINK A950RG 4.1.2cu.5268_B20221104 cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*

II. Public POCs for CVE-2026-121599

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-121599

请登录查看更多情报信息。

Other References for CVE-2026-121599 (5)

Same Patch Batch · TOTOLINK · 2026-11-04 · 4 CVEs total

CVE-2026-121597 9.9 CRITICAL TOTOLINK A950RG Easy Setup Wizard cstecgi.cgi setAppEasyWizardConfig stack-based overflow
CVE-2026-121598 9.9 CRITICAL TOTOLINK A950RG Basic Wireless Configuration cstecgi.cgi strcpy stack-based overflow
CVE-2026-121600 9.9 CRITICAL TOTOLINK A950RG MAC Filter cstecgi.cgi setMacFilterRules stack-based overflow

IV. Related Vulnerabilities