Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-1687— Tenda HG10 Boa Webserver formSamba command injection

Quick assessment

Affected
Tenda HG10
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda HG10是中国腾达(Tenda)公司的一个光猫路由器。 Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon存在命令注入漏洞,该漏洞源于Boa Webserver组件中/boaform/formSamba文件的未知函数对参数serverString的操作导致命令注入,可能导致远程命令执行。

CVSS 7.3 · High EPSS 3.23% · P88

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-1687

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda HG10 Boa Webserver formSamba command injection
Source: CVE Program / CVE List V5
Vulnerability Description
A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Source: CVE Program / CVE List V5
Vulnerability Type
在命令中使用的特殊元素转义处理不恰当(命令注入)
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda HG10 命令注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda HG10是中国腾达(Tenda)公司的一个光猫路由器。 Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon存在命令注入漏洞,该漏洞源于Boa Webserver组件中/boaform/formSamba文件的未知函数对参数serverString的操作导致命令注入,可能导致远程命令执行。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*

II. Public POCs for CVE-2026-1687

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-1687

请登录查看更多情报信息。

Proof of Concept for CVE-2026-1687 (2)

Same Patch Batch · Tenda · 2026-01-30 · 3 CVEs total

CVE-2026-1689 7.3 HIGH Tenda HG10 Login formLogin checkUserFromLanOrWan command injection
CVE-2026-1690 4.7 MEDIUM Tenda HG10 formSysCmd system command injection

IV. Related Vulnerabilities

V. Comments for CVE-2026-1687

No comments yet


Leave a comment