Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-19003— MongoDB BI Connector ODBC driver may write outside an allocated buffer when the setup dialog opens a data source with oversized path settings

Quick assessment

Affected
MongoDB BI Connector ODBC Driver
Exploitation
Public or AI PoC available; prioritize validation
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

MongoDB BI Connector ODBC Driver是美国MongoDB公司的一款数据库连接驱动软件。 MongoDB BI Connector ODBC Driver 1.0.0版本至1.4.9之前版本存在缓冲区错误漏洞,该漏洞源于文件和文件夹选择处理中缓冲区容量计算错误,可能导致进程异常终止,特定条件下执行未预期代码。

CVSS 7.8 · High EPSS 0.21% · P11

Possible ATT&CK Techniques 1 AI

T1203 · Exploitation for Client Execution

Affected Version Matrix 1

VendorProduct Version RangeStatus
MongoDB BI Connector ODBC Driver 1.0.0< 1.4.9 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-19003

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
MongoDB BI Connector ODBC driver may write outside an allocated buffer when the setup dialog opens a data source with oversized path settings
Source: CVE Program / CVE List V5
Vulnerability Description
A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5
Vulnerability Title
MongoDB BI Connector ODBC Driver 缓冲区错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
MongoDB BI Connector ODBC Driver是美国MongoDB公司的一款数据库连接驱动软件。 MongoDB BI Connector ODBC Driver 1.0.0版本至1.4.9之前版本存在缓冲区错误漏洞,该漏洞源于文件和文件夹选择处理中缓冲区容量计算错误,可能导致进程异常终止,特定条件下执行未预期代码。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
MongoDB BI Connector ODBC Driver 1.0.0 ~ 1.4.9 -

II. Public POCs for CVE-2026-19003

# POC Description Source Link Shenlong Link
AI-Generated POC Premium
Qwen3.6-35B-A3B · 124002 chars
Pro+ exclusive includes:
Vulnerability reproduction recording (real sandbox build + trigger, exclusive)
In-depth vulnerability mechanism
Trigger conditions & impact
Full executable POC code
Exploit chain & mitigation
POC zip download
100+ AI POC generations per month

III. Intelligence Information for CVE-2026-19003

请登录查看更多情报信息。

Vendor Pages for CVE-2026-19003 (1)

Same Patch Batch · MongoDB · 2026-08-12 · 7 CVEs total

CVE-2026-19001 9.8 CRITICAL MongoDB BI Connector ODBC driver may write outside an allocated buffer when handling overs
CVE-2026-19002 8.1 HIGH Crafted database metadata may cause memory corruption in MongoDB BI Connector ODBC Driver
CVE-2026-19004 8.1 HIGH MongoDB BI Connector ODBC Driver Memory-Safety Issue When Handling Stored Procedure Output
CVE-2026-18888 6.5 MEDIUM MongoDB BI Connector ODBC driver may write outside an allocated buffer when retrieving lar
CVE-2026-19502 5.5 MEDIUM Insufficient redaction of sensitive configuration values in diagnostic output of MongoDB S
CVE-2026-19503 4.8 MEDIUM Insufficient OIDC endpoint validation could invoke unintended local protocol handlers

IV. Related Vulnerabilities

V. Comments for CVE-2026-19003

No comments yet


Leave a comment