Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-19502— Insufficient redaction of sensitive configuration values in diagnostic output of MongoDB SQL Schema Builder CLI

Quick assessment

Affected
MongoDB Schema Builder CLI
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

MongoDB Schema Builder CLI是美国MongoDB公司的一款命令行模式构建工具。 MongoDB Schema Builder CLI 1.0.0版本至1.2.1之前版本存在日志信息泄露漏洞,该漏洞源于将启动配置记录到标准输出和日志文件,且未对某些连接设置进行脱敏,可能导致认证材料以明文形式泄露,本地用户或日志访问者可获取这些敏感信息。

CVSS 5.5 · Medium EPSS 0.12% · P2

Affected Version Matrix 1

VendorProduct Version RangeStatus
MongoDB Schema Builder CLI 1.0.0< 1.2.1 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-19502

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Insufficient redaction of sensitive configuration values in diagnostic output of MongoDB SQL Schema Builder CLI
Source: CVE Program / CVE List V5
Vulnerability Description
MongoDB SQL Schema Builder CLI records its startup configuration to standard output and, when file logging is enabled, to a log file on disk. Certain connection settings were written without redaction, so authentication material supplied by the operator could appear in plaintext in that diagnostic output. A local user with read access to the terminal session or the log directory, or anyone with access to a location where those logs are subsequently collected, could obtain those values.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Source: CVE Program / CVE List V5
Vulnerability Type
通过日志文件的信息暴露
Source: CVE Program / CVE List V5
Vulnerability Title
MongoDB Schema Builder CLI 日志信息泄露漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
MongoDB Schema Builder CLI是美国MongoDB公司的一款命令行模式构建工具。 MongoDB Schema Builder CLI 1.0.0版本至1.2.1之前版本存在日志信息泄露漏洞,该漏洞源于将启动配置记录到标准输出和日志文件,且未对某些连接设置进行脱敏,可能导致认证材料以明文形式泄露,本地用户或日志访问者可获取这些敏感信息。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
MongoDB Schema Builder CLI 1.0.0 ~ 1.2.1 -

II. Public POCs for CVE-2026-19502

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-19502

请登录查看更多情报信息。

Vendor Pages for CVE-2026-19502 (1)

Same Patch Batch · MongoDB · 2026-08-12 · 7 CVEs total

CVE-2026-19001 9.8 CRITICAL MongoDB BI Connector ODBC driver may write outside an allocated buffer when handling overs
CVE-2026-19002 8.1 HIGH Crafted database metadata may cause memory corruption in MongoDB BI Connector ODBC Driver
CVE-2026-19004 8.1 HIGH MongoDB BI Connector ODBC Driver Memory-Safety Issue When Handling Stored Procedure Output
CVE-2026-19003 7.8 HIGH MongoDB BI Connector ODBC driver may write outside an allocated buffer when the setup dial
CVE-2026-18888 6.5 MEDIUM MongoDB BI Connector ODBC driver may write outside an allocated buffer when retrieving lar
CVE-2026-19503 4.8 MEDIUM Insufficient OIDC endpoint validation could invoke unintended local protocol handlers

IV. Related Vulnerabilities

V. Comments for CVE-2026-19502

No comments yet


Leave a comment