Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-25720— SenseLive X3050 Insufficient session expiration

Quick assessment

Affected
SenseLive X3050
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

SenseLive X3050是日本SenseLive公司的一款面向物联网场景的数据采集与环境监测设备。 SenseLive X3050存在代码问题漏洞,该漏洞源于Web管理接口会话生命周期执行不当,可能导致已认证会话长时间保持活跃,攻击者利用先前认证的会话在合法用户活动停止后继续与管理员功能交互。

CVSS 5.4 · Medium EPSS 0.40% · P32
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-25720

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
SenseLive X3050 Insufficient session expiration
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability exists in SenseLive X3050’s web management interface due to improper session lifetime enforcement, allowing authenticated sessions to remain active for extended periods without requiring re-authentication. An attacker with access to a previously authenticated session could continue interacting with administrative functions long after legitimate user activity has ceased.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
Source: CVE Program / CVE List V5
Vulnerability Type
不充分的会话过期机制
Source: CVE Program / CVE List V5
Vulnerability Title
SenseLive X3050 代码问题漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
SenseLive X3050是日本SenseLive公司的一款面向物联网场景的数据采集与环境监测设备。 SenseLive X3050存在代码问题漏洞,该漏洞源于Web管理接口会话生命周期执行不当,可能导致已认证会话长时间保持活跃,攻击者利用先前认证的会话在合法用户活动停止后继续与管理员功能交互。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
SenseLive X3050 V1.523 -

II. Public POCs for CVE-2026-25720

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-25720

请登录查看更多情报信息。

Vendor Advisories for CVE-2026-25720 (1)

Same Patch Batch · SenseLive · 2026-04-23 · 7 CVEs total

CVE-2026-40630 9.8 CRITICAL SenseLive X3050 Authentication bypass using an alternate path or channel
CVE-2026-35503 9.8 CRITICAL SenseLive X3050 Use of Hard-coded Credentials
CVE-2026-27843 9.1 CRITICAL SenseLive X3050 Missing authentication for critical function
CVE-2026-39462 8.1 HIGH SenseLive X3050 Insufficiently Protected Credentials
CVE-2026-40623 8.1 HIGH SenseLive X3050 Missing Authorization
CVE-2026-40431 5.3 MEDIUM SenseLive X3050 Cleartext transmission of sensitive information

IV. Related Vulnerabilities

V. Comments for CVE-2026-25720

No comments yet


Leave a comment