Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-2910— Tenda HG9 formPing6 stack-based overflow

Quick assessment

Affected
Tenda HG9
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda HG9是中国腾达(Tenda)公司的一款WiFi路由器。 Tenda HG9 300001138版本存在安全漏洞,该漏洞源于对文件/boaform/formPing6中参数pingAddr的错误操作,可能导致栈缓冲区溢出。

CVSS 8.8 · High EPSS 1.03% · P62
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-2910

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda HG9 formPing6 stack-based overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda HG9 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda HG9是中国腾达(Tenda)公司的一款WiFi路由器。 Tenda HG9 300001138版本存在安全漏洞,该漏洞源于对文件/boaform/formPing6中参数pingAddr的错误操作,可能导致栈缓冲区溢出。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda HG9 300001138 -

II. Public POCs for CVE-2026-2910

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-2910

请登录查看更多情报信息。

Same Patch Batch · Tenda · 2026-02-22 · 8 CVEs total

CVE-2026-2911 8.8 HIGH Tenda FH451 GstDhcpSetSer buffer overflow
CVE-2026-2909 8.8 HIGH Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow
CVE-2026-2908 8.8 HIGH Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow
CVE-2026-2907 8.8 HIGH Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow
CVE-2026-2906 8.8 HIGH Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow
CVE-2026-2905 8.8 HIGH Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow
CVE-2026-2930 6.3 MEDIUM Tenda A18 Httpd Service UploadCfg webCgiGetUploadFile stack-based overflow

IV. Related Vulnerabilities

V. Comments for CVE-2026-2910

No comments yet


Leave a comment