Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2026-33570— Subnet Solutions PowerSYSTEM Center Incorrect Authorization

CVSS 5.7 · Medium EPSS 0.01% · P3

Possible ATT&CK Techniques 1AI

T1528 · Steal Application Access Token

Affected Version Matrix 1

VendorProductVersion RangeStatus
Subnet SolutionsPowerSYSTEM Center 20205.11.x≤ 5.28.xaffected
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2026-33570

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Subnet Solutions PowerSYSTEM Center Incorrect Authorization
Source: NVD (National Vulnerability Database)
Vulnerability Description
PowerSYSTEM Center REST API endpoint for devices allows a low privilege authenticated user to access information normally limited by operational permissions.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Source: NVD (National Vulnerability Database)
Vulnerability Type
授权机制不正确
Source: NVD (National Vulnerability Database)
Vulnerability Title
Subnet Solutions PowerSYSTEM Center 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Subnet Solutions PowerSYSTEM Center是Subnet Solutions公司的一个电力解决方案。 Subnet Solutions PowerSYSTEM Center存在安全漏洞,该漏洞源于设备端点允许低权限认证用户访问通常受操作权限限制的信息。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
Subnet SolutionsPowerSYSTEM Center 2020 5.11.x ~ 5.28.x -

II. Public POCs for CVE-2026-33570

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-33570

登录查看更多情报信息。

Same Patch Batch · Subnet Solutions · 2026-05-12 · 4 CVEs total

CVE-2026-262898.2 HIGHSubnet Solutions PowerSYSTEM Center Incorrect Authorization
CVE-2026-355556.3 MEDIUMSubnet Solutions PowerSYSTEM Center Incorrect Authorization
CVE-2026-355045.5 MEDIUMSubnet Solutions PowerSYSTEM Center CRLF injection

IV. Related Vulnerabilities

V. Comments for CVE-2026-33570

No comments yet


Leave a comment