Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-44724— systeminformation: Linux command injection in networkInterfaces() via unsanitized NetworkManager connection profile name

Quick assessment

Affected
sebhildebrandt systeminformation
Exploitation
Public or AI PoC available; prioritize validation
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

systeminformation是Sebastian Hildebrandt个人开发者的一个可以获得操作系统信息的 Npm 软件库。 systeminformation 4.17.0至5.31.5版本存在操作系统命令注入漏洞,该漏洞源于在Linux上,当NetworkManager连接配置文件名称包含shell元字符时,networkInterfaces()存在命令注入,未对解析的NetworkManager连接配置文件名称进行清理,导致其被插入到通过execSync()执行的shell命令字符串中。

CVSS 7.8 · High EPSS 1.15% · P66

Possible ATT&CK Techniques 1 AI

T1059 · Command and Scripting Interpreter

Affected Version Matrix 1

VendorProduct Version RangeStatus
sebhildebrandt systeminformation >= 4.17.0, < 5.31.6 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-44724

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
systeminformation: Linux command injection in networkInterfaces() via unsanitized NetworkManager connection profile name
Source: CVE Program / CVE List V5
Vulnerability Description
systeminformation is a System and OS information library for node.js. From 4.17.0 to 5.31.5, on Linux, systeminformation is vulnerable to command injection in networkInterfaces() when an active NetworkManager connection profile name contains shell metacharacters. The vulnerable value is obtained internally from real nmcli device status output. The library sanitizes the network interface name before using it in shell commands, but it does not apply equivalent sanitization to the parsed NetworkManager connection profile name. That unsanitized connectionName is then interpolated into three shell command strings executed through execSync(). This vulnerability is fixed in 5.31.6.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
OS命令中使用的特殊元素转义处理不恰当(OS命令注入)
Source: CVE Program / CVE List V5
Vulnerability Title
systeminformation 操作系统命令注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
systeminformation是Sebastian Hildebrandt个人开发者的一个可以获得操作系统信息的 Npm 软件库。 systeminformation 4.17.0至5.31.5版本存在操作系统命令注入漏洞,该漏洞源于在Linux上,当NetworkManager连接配置文件名称包含shell元字符时,networkInterfaces()存在命令注入,未对解析的NetworkManager连接配置文件名称进行清理,导致其被插入到通过execSync()执行的shell命令字符串中。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
sebhildebrandt systeminformation >= 4.17.0, < 5.31.6 -

II. Public POCs for CVE-2026-44724

# POC Description Source Link Shenlong Link
AI-Generated POC Premium
Qwen3.6-35B-A3B · 6846 chars
Pro+ exclusive includes:
Vulnerability reproduction recording (real sandbox build + trigger, exclusive)
In-depth vulnerability mechanism
Trigger conditions & impact
Full executable POC code
Exploit chain & mitigation
POC zip download
100+ AI POC generations per month

III. Intelligence Information for CVE-2026-44724

请登录查看更多情报信息。

Vendor Advisories for CVE-2026-44724 (1)

IV. Related Vulnerabilities

V. Comments for CVE-2026-44724

No comments yet


Leave a comment