Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-5021— Tenda F453 httpd PPTPUserSetting fromPPTPUserSetting stack-based overflow

Quick assessment

Affected
Tenda F453
Exploitation
Public or AI PoC available; prioritize validation
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda F453是中国腾达(Tenda)公司的一款无线路由器。 Tenda F453 1.0.0.3版本存在安全漏洞,该漏洞源于组件httpd中文件/goform/PPTPUserSetting的函数fromPPTPUserSetting对参数delno操作不当,可能导致栈缓冲区溢出。

CVSS 8.8 · High EPSS 1.01% · P62

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-5021

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda F453 httpd PPTPUserSetting fromPPTPUserSetting stack-based overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A flaw has been found in Tenda F453 1.0.0.3. This affects the function fromPPTPUserSetting of the file /goform/PPTPUserSetting of the component httpd. This manipulation of the argument delno causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda F453 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda F453是中国腾达(Tenda)公司的一款无线路由器。 Tenda F453 1.0.0.3版本存在安全漏洞,该漏洞源于组件httpd中文件/goform/PPTPUserSetting的函数fromPPTPUserSetting对参数delno操作不当,可能导致栈缓冲区溢出。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda F453 1.0.0.3 cpe:2.3:o:tenda:f453_firmware:*:*:*:*:*:*:*:*

II. Public POCs for CVE-2026-5021

# POC Description Source Link Shenlong Link
AI-Generated POC Premium
Qwen3.6-35B-A3B · 6919 chars
Pro+ exclusive includes:
Vulnerability reproduction recording (real sandbox build + trigger, exclusive)
In-depth vulnerability mechanism
Trigger conditions & impact
Full executable POC code
Exploit chain & mitigation
POC zip download
100+ AI POC generations per month

III. Intelligence Information for CVE-2026-5021

请登录查看更多情报信息。

Vendor Advisories for CVE-2026-5021 (2)

Other References for CVE-2026-5021 (1)

Same Patch Batch · Tenda · 2026-03-29 · 4 CVEs total

CVE-2026-5046 8.8 HIGH Tenda FH1201 Parameter WrlExtraSet formWrlExtraSet stack-based overflow
CVE-2026-5045 8.8 HIGH Tenda FH1201 Parameter WrlclientSet stack-based overflow
CVE-2026-5036 8.8 HIGH Tenda 4G06 Endpoint DhcpListClient fromDhcpListClient stack-based overflow

IV. Related Vulnerabilities

V. Comments for CVE-2026-5021

No comments yet


Leave a comment