Affected
Siemens SIMATIC S7-PLCSIM Advanced
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Siemens simatic s7-plcsim advanced是德国Siemens公司的一款高级可编程控制器仿真工具。 Siemens simatic s7-plcsim advanced存在资源管理错误漏洞,该漏洞源于未正确处理高容量组播网络流量,可能导致本地网络段上未经身份验证的攻击者耗尽可用内存资源,从而造成拒绝服务。以下版本受到影响:所有版本。

CVSS 7.4 · High EPSS 0.27% · P17

Possible ATT&CK Techniques 1 AI

T1499 · Endpoint Denial of Service

Affected Version Matrix 1

VendorProduct Version RangeStatus
Siemens SIMATIC S7-PLCSIM Advanced < * affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-54429

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability has been identified in SIMATIC S7-PLCSIM Advanced (All versions). Affected devices do not properly handle high-volume multicast network traffic, which can exhaust available memory resources in the affected application. This could allow an unauthenticated attacker on the local network segment to cause a denial-of-service condition of the affected application. The affected application becomes inaccessible and requires a manual restart; no project data is lost. Successful exploitation requires a specific project configuration to be already active on the targeted instance.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
不加限制或调节的资源分配
Source: CVE Program / CVE List V5
Vulnerability Title
Siemens simatic s7-plcsim advanced 资源管理错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens simatic s7-plcsim advanced是德国Siemens公司的一款高级可编程控制器仿真工具。 Siemens simatic s7-plcsim advanced存在资源管理错误漏洞,该漏洞源于未正确处理高容量组播网络流量,可能导致本地网络段上未经身份验证的攻击者耗尽可用内存资源,从而造成拒绝服务。以下版本受到影响:所有版本。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Siemens SIMATIC S7-PLCSIM Advanced 0 ~ * -

II. Public POCs for CVE-2026-54429

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-54429

请登录查看更多情报信息。

Vendor Advisories for CVE-2026-54429 (1)

Same Patch Batch · Siemens · 2026-07-14 · 3 CVEs total

CVE-2026-56451 10.0 CRITICAL Siemens Opcenter X 加密问题漏洞
CVE-2025-40945 6.7 MEDIUM Siemens COMOS 权限许可和访问控制问题漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2026-54429

No comments yet


Leave a comment