Juniper Networks Junos OS是美国Juniper Networks公司的一款专为路由器、交换机和防火墙等物理及虚拟设备打造的网络操作系统。 Juniper Networks Junos OS存在异常处理不当漏洞,该漏洞源于数据包转发引擎中对异常情况检查不当,可能导致未经身份验证的邻近攻击者造成拒绝服务。以下版本受到影响:QFX10000 Series所有23.2R2-S7之前版本、23.4版本中23.4R2-S8之前版本、24.2版本中24.2R2-S4之前版本和24.4版本中24.
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| Juniper Networks | Junos OS | < 23.2R2-S7 |
affected |
23.4< 23.4R2-S8 |
affected | ||
24.2< 24.2R2-S4 |
affected | ||
24.4< 24.4R2-S4 |
affected |
Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.
| Vendor | Product | Affected Versions | CPE | Subscribe |
|---|---|---|---|---|
| Juniper Networks | Junos OS | 0 ~ 23.2R2-S7 | - |
|
| # | POC Description | Source Link | Shenlong Link |
|---|
No public POC found.
Login to generate AI POC| CVE-2026-57023 | 7.5 HIGH | Junos OS: MX with SPC3, SRX Series: A specifically malformed TCP packet causes a flowd cra |
| CVE-2026-57026 | 7.5 HIGH | Junos OS: MX Series with SPC3, SRX Series: Processing of a specifically malformed SIP invi |
| CVE-2026-57028 | 7.3 HIGH | Junos OS Evolved: A port which has been inadvertently exposed can be reached by an attacke |
| CVE-2026-57032 | 6.5 MEDIUM | Junos OS: EX Series: Subscribing to an unsupported telemetry sensor path causes fxpc proce |
| CVE-2026-33800 | 6.5 MEDIUM | Junos OS: MX Series: In a VC scenario a high rate of micro-BFD session flaps will cause an |
| CVE-2026-33801 | 6.5 MEDIUM | Junos OS and Junos OS Evolved: When a specifically malformed BGP route update is received |
| CVE-2026-33803 | 6.5 MEDIUM | Junos OS Evolved: A port which has been inadvertently exposed can be reached by an attacke |
| CVE-2026-57019 | 6.5 MEDIUM | Junos OS: MX Series: Specific traffic causes an FPC to reset |
| CVE-2026-57027 | 6.5 MEDIUM | Junos OS: EX4100 Series, EX4400: With sFlow configured in a VC scenario multicast traffic |
| CVE-2026-57022 | 5.9 MEDIUM | Junos OS: MX Series with SPC3, SRX Series: Specific packet in response to a TCP connection |
| CVE-2026-57030 | 5.9 MEDIUM | Junos OS: SRX Series: Flow sessions are not getting cleared leading to a DoS |
| CVE-2026-33794 | 5.9 MEDIUM | Junos OS Evolved: PTX Series: Receipt of repeated ECMP routing updates results in PFE cras |
| CVE-2026-57054 | 5.8 MEDIUM | Junos OS: MX Series: Web filtering doesn't block specifically formatted URLs |
| CVE-2026-57025 | 5.5 MEDIUM | Junos OS and Junos OS Evolved: EX Series, QFX Series, MX Series: A specific 'show l2-learn |
| CVE-2026-33802 | 5.5 MEDIUM | Junos OS: EX Series: Unauthorized users can execute service-impacting CLI command |
| CVE-2026-57024 | 5.3 MEDIUM | Junos OS: MX with SPC3, SRX Series: Repeated VPN negotiation failures will eventually caus |
| CVE-2026-57021 | 5.3 MEDIUM | Junos OS: SRX Series: If VPN compliance-check is configured an attacker can cause http-gk |
| CVE-2026-57029 | 5.3 MEDIUM | Junos OS Evolved: QFX Series: When sFlow collector reachability changes evo-pfemand proces |
| CVE-2026-57031 | 4.7 MEDIUM | Junos OS: MX Series: For subscribers configured on static interfaces, input filters are no |
| CVE-2026-21901 | 4.4 MEDIUM | Junos OS and Junos OS Evolved: Configuration of a specific SSH option results in mgd crash |
Showing top 20 of 22 CVEs. View all on vendor page → →