Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2026-57027— Junos OS: EX4100 Series, EX4400: With sFlow configured in a VC scenario multicast traffic leads to an FPC crash

Quick assessment

Affected
Juniper Networks Junos OS
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Juniper Networks Junos OS是美国Juniper Networks公司的一款专为路由器、交换机和防火墙等物理及虚拟设备打造的网络操作系统。 Juniper Networks Junos OS存在资源管理错误漏洞,该漏洞源于数据包转发引擎(pfe)缺少有效内存释放,可能导致未经验证的相邻攻击者造成拒绝服务。以下版本受到影响:23.2R2-S7之前版本、23.4R2-S7之前的23.4版本、24.2R2-S4之前的24.2版本和24.4R2之前的24.4版本。

CVSS 6.5 · Medium EPSS 0.17% · P6

Affected Version Matrix 4

VendorProduct Version RangeStatus
Juniper Networks Junos OS < 23.2R2-S7 affected
23.4< 23.4R2-S7 affected
24.2< 24.2R2-S4 affected
24.4< 24.4R2 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-57027

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Junos OS: EX4100 Series, EX4400: With sFlow configured in a VC scenario multicast traffic leads to an FPC crash
Source: CVE Program / CVE List V5
Vulnerability Description
A Missing Release of Memory after Effective Lifetime vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on specific EX Series devices allows an unauthenticated adjacent attacker to cause a Denial-of-Service (DoS).When sFlow is configured in a Virtual Chassis (VC) scenario with EX4100 Series or EX4400 Series devices, multicast traffic which is received on one VC member and sent out on another member leads to a memory leak and ultimately an FPC crash and restart. The leak can be monitored by watching the continuous increase of the buffer values in the output of: user@host> show chassis fpc This issue affects Junos OS on EX4100 Series and EX4400: * all versions before 23.2R2-S7, * 23.4 versions before 23.4R2-S7, * 24.2 versions before 24.2R2-S4, * 24.4 versions before 24.4R2.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
在移除最后引用时对内存的释放不恰当(内存泄露)
Source: CVE Program / CVE List V5
Vulnerability Title
Juniper Networks Junos OS 资源管理错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Juniper Networks Junos OS是美国Juniper Networks公司的一款专为路由器、交换机和防火墙等物理及虚拟设备打造的网络操作系统。 Juniper Networks Junos OS存在资源管理错误漏洞,该漏洞源于数据包转发引擎(pfe)缺少有效内存释放,可能导致未经验证的相邻攻击者造成拒绝服务。以下版本受到影响:23.2R2-S7之前版本、23.4R2-S7之前的23.4版本、24.2R2-S4之前的24.2版本和24.4R2之前的24.4版本。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Juniper Networks Junos OS 0 ~ 23.2R2-S7 -

II. Public POCs for CVE-2026-57027

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-57027

登录查看更多情报信息。

Vendor Advisories for CVE-2026-57027 (1)

Same Patch Batch · Juniper Networks · 2026-07-09 · 22 CVEs total

CVE-2026-57026 7.5 HIGH Junos OS: MX Series with SPC3, SRX Series: Processing of a specifically malformed SIP invi
CVE-2026-57023 7.5 HIGH Junos OS: MX with SPC3, SRX Series: A specifically malformed TCP packet causes a flowd cra
CVE-2026-57028 7.3 HIGH Junos OS Evolved: A port which has been inadvertently exposed can be reached by an attacke
CVE-2026-57032 6.5 MEDIUM Junos OS: EX Series: Subscribing to an unsupported telemetry sensor path causes fxpc proce
CVE-2026-33800 6.5 MEDIUM Junos OS: MX Series: In a VC scenario a high rate of micro-BFD session flaps will cause an
CVE-2026-33801 6.5 MEDIUM Junos OS and Junos OS Evolved: When a specifically malformed BGP route update is received
CVE-2026-33803 6.5 MEDIUM Junos OS Evolved: A port which has been inadvertently exposed can be reached by an attacke
CVE-2026-57019 6.5 MEDIUM Junos OS: MX Series: Specific traffic causes an FPC to reset
CVE-2026-57020 6.5 MEDIUM Junos OS: QFX10000 Series: IPv6 multicast traffic received on non-IRB interfaces causes a
CVE-2026-57022 5.9 MEDIUM Junos OS: MX Series with SPC3, SRX Series: Specific packet in response to a TCP connection
CVE-2026-33794 5.9 MEDIUM Junos OS Evolved: PTX Series: Receipt of repeated ECMP routing updates results in PFE cras
CVE-2026-57030 5.9 MEDIUM Junos OS: SRX Series: Flow sessions are not getting cleared leading to a DoS
CVE-2026-57054 5.8 MEDIUM Junos OS: MX Series: Web filtering doesn't block specifically formatted URLs
CVE-2026-57025 5.5 MEDIUM Junos OS and Junos OS Evolved: EX Series, QFX Series, MX Series: A specific 'show l2-learn
CVE-2026-33802 5.5 MEDIUM Junos OS: EX Series: Unauthorized users can execute service-impacting CLI command
CVE-2026-57021 5.3 MEDIUM Junos OS: SRX Series: If VPN compliance-check is configured an attacker can cause http-gk
CVE-2026-57024 5.3 MEDIUM Junos OS: MX with SPC3, SRX Series: Repeated VPN negotiation failures will eventually caus
CVE-2026-57029 5.3 MEDIUM Junos OS Evolved: QFX Series: When sFlow collector reachability changes evo-pfemand proces
CVE-2026-57031 4.7 MEDIUM Junos OS: MX Series: For subscribers configured on static interfaces, input filters are no
CVE-2026-21901 4.4 MEDIUM Junos OS and Junos OS Evolved: Configuration of a specific SSH option results in mgd crash

Showing top 20 of 22 CVEs. View all on vendor page &rarr; →

IV. Related Vulnerabilities

V. Comments for CVE-2026-57027

No comments yet


Leave a comment