Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-6124— Tenda F451 httpd SafeMacFilter fromSafeMacFilter stack-based overflow

Quick assessment

Affected
Tenda F451
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda F451是中国腾达(Tenda)公司的一款无线路由器。 Tenda F451 1.0.0.7版本存在安全漏洞,该漏洞源于httpd组件中文件/goform/SafeMacFilter的fromSafeMacFilter函数对参数page/menufacturer处理不当,可能导致栈缓冲区溢出。

CVSS 8.8 · High EPSS 0.95% · P60

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-6124

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda F451 httpd SafeMacFilter fromSafeMacFilter stack-based overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability was determined in Tenda F451 1.0.0.7. This vulnerability affects the function fromSafeMacFilter of the file /goform/SafeMacFilter of the component httpd. Executing a manipulation of the argument page/menufacturer can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda F451 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda F451是中国腾达(Tenda)公司的一款无线路由器。 Tenda F451 1.0.0.7版本存在安全漏洞,该漏洞源于httpd组件中文件/goform/SafeMacFilter的fromSafeMacFilter函数对参数page/menufacturer处理不当,可能导致栈缓冲区溢出。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda F451 1.0.0.7 cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*

II. Public POCs for CVE-2026-6124

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-6124

请登录查看更多情报信息。

Same Patch Batch · Tenda · 2026-04-12 · 10 CVEs total

CVE-2026-6137 8.8 HIGH Tenda F451 AdvSetWan fromAdvSetWan stack-based overflow
CVE-2026-6136 8.8 HIGH Tenda F451 L7Im frmL7ImForm stack-based overflow
CVE-2026-6135 8.8 HIGH Tenda F451 SetIpBind fromSetIpBind stack-based overflow
CVE-2026-6134 8.8 HIGH Tenda F451 qossetting fromqossetting stack-based overflow
CVE-2026-6133 8.8 HIGH Tenda F451 SafeUrlFilter fromSafeUrlFilter stack-based overflow
CVE-2026-6123 8.8 HIGH Tenda F451 httpd addressNat fromAddressNat stack-based overflow
CVE-2026-6122 8.8 HIGH Tenda F451 httpd L7Prot frmL7ProtForm stack-based overflow
CVE-2026-6121 8.8 HIGH Tenda F451 httpd WrlclientSet stack-based overflow
CVE-2026-6120 8.8 HIGH Tenda F451 httpd DhcpListClient fromDhcpListClient stack-based overflow

IV. Related Vulnerabilities

V. Comments for CVE-2026-6124

No comments yet


Leave a comment