Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-7151— Tenda HG3 formIPv6Routing formUploadConfig stack-based overflow

Quick assessment

Affected
Tenda HG3
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda HG3是中国腾达(Tenda)公司的一款面向家庭宽带接入的光纤网络终端无线路由设备。 Tenda HG3 2.0版本存在缓冲区错误漏洞,该漏洞源于文件/boaform/formIPv6Routing中函数formUploadConfig对参数destNet操作不当,可能导致栈缓冲区溢出。

CVSS 8.8 · High EPSS 1.01% · P62

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application

Affected Version Matrix 1

VendorProduct Version RangeStatus
Tenda HG3 2.0 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-7151

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda HG3 formIPv6Routing formUploadConfig stack-based overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability was determined in Tenda HG3 2.0. Impacted is the function formUploadConfig of the file /boaform/formIPv6Routing. This manipulation of the argument destNet causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda HG3 缓冲区错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda HG3是中国腾达(Tenda)公司的一款面向家庭宽带接入的光纤网络终端无线路由设备。 Tenda HG3 2.0版本存在缓冲区错误漏洞,该漏洞源于文件/boaform/formIPv6Routing中函数formUploadConfig对参数destNet操作不当,可能导致栈缓冲区溢出。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda HG3 2.0 -

II. Public POCs for CVE-2026-7151

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-7151

请登录查看更多情报信息。

Vendor Advisories for CVE-2026-7151 (1)

Security Blog Posts for CVE-2026-7151 (1)

Same Patch Batch · Tenda · 2026-04-27 · 15 CVEs total

CVE-2026-7078 8.8 HIGH Tenda F456 httpd SetIpBind fromSetIpBind buffer overflow
CVE-2026-7079 8.8 HIGH Tenda F456 httpd AdvSetWan fromAdvSetWan buffer overflow
CVE-2026-7080 8.8 HIGH Tenda F456 httpd PPTPUserSetting fromPPTPUserSetting buffer overflow
CVE-2026-7081 8.8 HIGH Tenda F456 httpd GstDhcpSetSer fromGstDhcpSetSer buffer overflow
CVE-2026-7082 8.8 HIGH Tenda F456 httpd WrlExtraSet formWrlExtraSet buffer overflow
CVE-2026-7096 8.8 HIGH Tenda HG3 formgponConf os command injection
CVE-2026-7097 8.8 HIGH Tenda F456 httpd webExcptypemanFilter fromwebExcptypemanFilter buffer overflow
CVE-2026-7098 8.8 HIGH Tenda F456 httpd DhcpListClient fromDhcpListClient buffer overflow
CVE-2026-7099 8.8 HIGH Tenda F456 httpd QuickIndex formQuickIndex buffer overflow
CVE-2026-7100 8.8 HIGH Tenda F456 httpd Natlimit fromNatlimitof buffer overflow
CVE-2026-7101 8.8 HIGH Tenda F456 httpd WrlclientSet fromWrlclientSet buffer overflow
CVE-2026-7119 8.8 HIGH Tenda HG3 formCountrystr os command injection
CVE-2026-7160 8.8 HIGH Tenda HG3 formTracert command injection
CVE-2026-7102 6.3 MEDIUM Tenda F456 httpd WriteFacMac FromWriteFacMac command injection

IV. Related Vulnerabilities

V. Comments for CVE-2026-7151

No comments yet


Leave a comment