CVE-2026-85109— Tenda HG10 Boa Web Server formLogin buffer overflow

Quick assessment

Affected
Tenda HG10
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda hg10 firmware是中国Tenda公司的一款信息化产品。 Tenda hg10 firmware 300001138版本存在缓冲区错误漏洞,该漏洞源于Boa Web Server组件中文件/boaform/formLogin的formLogin函数对Username参数操作不当,可能导致缓冲区溢出。攻击者可远程利用,漏洞利用代码已公开。

CVSS 9.8 · Critical EPSS 0.62% · P47

Affected Version Matrix 1

VendorProduct Version RangeStatus
Tenda HG10 300001138 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-85109

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda HG10 Boa Web Server formLogin buffer overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formLogin of the file /boaform/formLogin of the component Boa Web Server. Executing a manipulation of the argument Username can lead to buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
未进行输入大小检查的缓冲区拷贝(传统缓冲区溢出)
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda hg10 firmware 缓冲区错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda hg10 firmware是中国Tenda公司的一款信息化产品。 Tenda hg10 firmware 300001138版本存在缓冲区错误漏洞,该漏洞源于Boa Web Server组件中文件/boaform/formLogin的formLogin函数对Username参数操作不当,可能导致缓冲区溢出。攻击者可远程利用,漏洞利用代码已公开。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda HG10 300001138 cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*

II. Public POCs for CVE-2026-85109

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-85109

登录查看更多情报信息。

Proof of Concept for CVE-2026-85109 (1)

News Coverage for CVE-2026-85109 (1)

Other References for CVE-2026-85109 (2)

IV. Related Vulnerabilities

V. Comments for CVE-2026-85109

No comments yet


Leave a comment