Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2026-86165— Tenda HG10 formURL buffer overflow

Quick assessment

Affected
Tenda HG10
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

在 Tenda HG10 300001138 中发现了一个漏洞。该漏洞影响 文件中的 函数。对参数 进行操纵可导致缓冲区溢出。该攻击可远程发起。利用方法已公开,可能被利用。

CVSS 9.8 · Critical

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-86165

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda HG10 formURL buffer overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability was found in Tenda HG10 300001138. This vulnerability affects the function formURL of the file /boaform/admin/formURL. Performing a manipulation of the argument Keywd/urlFQDN results in buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
未进行输入大小检查的缓冲区拷贝(传统缓冲区溢出)
Source: CVE Program / CVE List V5

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda HG10 300001138 cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*

II. Public POCs for CVE-2026-86165

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-86165

登录查看更多情报信息。

Vendor Advisories for CVE-2026-86165 (3)

Proof of Concept for CVE-2026-86165 (1)

Other References for CVE-2026-86165 (1)

Same Patch Batch · Tenda · 2026-09-06 · 5 CVEs total

CVE-2026-86152 10.0 CRITICAL Tenda CP3 Kylin AutoAddWifi.cpp ThreadProc os command injection
CVE-2026-86167 9.9 CRITICAL Tenda HG10 Boa formgponConf os command injection
CVE-2026-86153 9.1 CRITICAL Tenda CP3 Redirect.cpp SetRedirectEnable privileges management
CVE-2026-86166 8.8 HIGH Tenda HG10 Boa Web Server formWanRedirect buffer overflow

IV. Related Vulnerabilities

V. Comments for CVE-2026-86165

No comments yet


Leave a comment