Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-9297— Edimax BR-6428NS POST Request formWlbasic command injection

Quick assessment

Affected
Edimax BR-6428NS
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Edimax BR-6428nS是中国讯舟(Edimax)公司的一款无线路由器。 Edimax BR-6428nS 1.10版本存在命令注入漏洞,该漏洞源于POST请求处理程序中/goform/formWlbasic文件formWlbasic函数对参数repeaterSSID操作不当,可能导致命令注入。

CVSS 6.3 · Medium EPSS 2.38% · P83

Affected Version Matrix 1

VendorProduct Version RangeStatus
Edimax BR-6428NS 1.10 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-9297

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Edimax BR-6428NS POST Request formWlbasic command injection
Source: CVE Program / CVE List V5
Vulnerability Description
A security vulnerability has been detected in Edimax BR-6428NS 1.10. Affected is the function formWlbasic of the file /goform/formWlbasic of the component POST Request Handler. The manipulation of the argument repeaterSSID leads to command injection. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Source: CVE Program / CVE List V5
Vulnerability Type
在命令中使用的特殊元素转义处理不恰当(命令注入)
Source: CVE Program / CVE List V5
Vulnerability Title
Edimax BR-6428nS 命令注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Edimax BR-6428nS是中国讯舟(Edimax)公司的一款无线路由器。 Edimax BR-6428nS 1.10版本存在命令注入漏洞,该漏洞源于POST请求处理程序中/goform/formWlbasic文件formWlbasic函数对参数repeaterSSID操作不当,可能导致命令注入。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Edimax BR-6428NS 1.10 cpe:2.3:o:edimax:br-6428ns_firmware:*:*:*:*:*:*:*:*

II. Public POCs for CVE-2026-9297

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-9297

请登录查看更多情报信息。

News Coverage for CVE-2026-9297 (1)

Same Patch Batch · Edimax · 2026-05-23 · 5 CVEs total

CVE-2026-9295 8.8 HIGH Edimax BR-6428NS POST Request formWirelessTbl buffer overflow
CVE-2026-9294 8.8 HIGH Edimax BR-6428NS POST Request formWanTcpipSetup buffer overflow
CVE-2026-9343 6.3 MEDIUM Edimax EW-7438RPn webs formWpsStart os command injection
CVE-2026-9296 6.3 MEDIUM Edimax BR-6428NS POST Request formWlanM system command injection