Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-9514— Totolink CA750-PoE Setting cstecgi.cgi setNetworkDiag os command injection

Quick assessment

Affected
Totolink CA750-PoE
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

TOTOLINK CA750-PoE是中国吉翁电子(TOTOLINK)公司的一款无线网络接入设备。 TOTOLINK CA750-PoE 6.2c.510版本存在操作系统命令注入漏洞,该漏洞源于Setting Handler组件中/cgi-bin/cstecgi.cgi文件的setNetworkDiag函数对参数NetDiagHost/NetDiagPingNum/NetDiagPingSize/NetDiagPingTimeOut/NetDiagTracertHop的操作存在os命令注入,可能导致远程攻

CVSS 6.3 · Medium EPSS 1.77% · P77

Affected Version Matrix 1

VendorProduct Version RangeStatus
Totolink CA750-PoE 6.2c.510 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-9514

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Totolink CA750-PoE Setting cstecgi.cgi setNetworkDiag os command injection
Source: CVE Program / CVE List V5
Vulnerability Description
A security vulnerability has been detected in Totolink CA750-PoE 6.2c.510. Impacted is the function setNetworkDiag of the file /cgi-bin/cstecgi.cgi of the component Setting Handler. The manipulation of the argument NetDiagHost/NetDiagPingNum/NetDiagPingSize/NetDiagPingTimeOut/NetDiagTracertHop is directly passed by the attacker/so we can control the NetDiagHost/NetDiagPingNum/NetDiagPingSize/NetDiagPingTimeOut/NetDiagTracertHop leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Source: CVE Program / CVE List V5
Vulnerability Type
OS命令中使用的特殊元素转义处理不恰当(OS命令注入)
Source: CVE Program / CVE List V5
Vulnerability Title
TOTOLINK CA750-PoE 操作系统命令注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
TOTOLINK CA750-PoE是中国吉翁电子(TOTOLINK)公司的一款无线网络接入设备。 TOTOLINK CA750-PoE 6.2c.510版本存在操作系统命令注入漏洞,该漏洞源于Setting Handler组件中/cgi-bin/cstecgi.cgi文件的setNetworkDiag函数对参数NetDiagHost/NetDiagPingNum/NetDiagPingSize/NetDiagPingTimeOut/NetDiagTracertHop的操作存在os命令注入,可能导致远程攻
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Totolink CA750-PoE 6.2c.510 cpe:2.3:a:totolink:ca750-poe:*:*:*:*:*:*:*:*

II. Public POCs for CVE-2026-9514

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-9514

请登录查看更多情报信息。

Other References for CVE-2026-9514 (1)

Same Patch Batch · Totolink · 2026-05-25 · 20 CVEs total

CVE-2026-9457 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi UploadFirmwareFile os command injection
CVE-2026-9408 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setStaticDhcpRules os command injection
CVE-2026-9432 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setWiFiAdvancedCfg os command injection
CVE-2026-9433 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setMacFilterRules os command injection
CVE-2026-9434 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setWiFiWpsCfg os command injection
CVE-2026-9435 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setQosCfg os command injection
CVE-2026-9436 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setL2tpServerCfg os command injection
CVE-2026-9454 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setOpenVpnCertGenerationCfg os command injecti
CVE-2026-9455 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi UploadOpenVpnCert os command injection
CVE-2026-9456 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setOpenVpnCfg os command injection
CVE-2026-9458 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setWanCfg os command injection
CVE-2026-9475 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setIpQosRules os command injection
CVE-2026-9476 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setPasswordCfg os command injection
CVE-2026-9477 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setAccessDeviceCfg os command injection
CVE-2026-9478 9.8 CRITICAL Totolink A8000RU Web Management cstecgi.cgi setParentalRules os command injection
CVE-2026-9515 6.3 MEDIUM Totolink CA750-PoE Setting cstecgi.cgi setUnloadUserData os command injection
CVE-2026-9511 6.3 MEDIUM Totolink CA750-PoE Setting cstecgi.cgi setWebWlanIdx os command injection
CVE-2026-9512 6.3 MEDIUM Totolink CA750-PoE Setting cstecgi.cgi setPasswordCfg os command injection
CVE-2026-9513 6.3 MEDIUM Totolink CA750-PoE Setting cstecgi.cgi NTPSyncWithHost os command injection

IV. Related Vulnerabilities

V. Comments for CVE-2026-9514

No comments yet