CVE-2026-9735— Keyfile contents are in MongoDB Server logs

CVSS 5.5 · Medium EPSS 0.12% · P2

Possible ATT&CK Techniques 1AI

T1530 · Data from Cloud Storage

Affected Version Matrix 1

VendorProductVersion RangeStatus
MongoDBMongoDB Server8.3.0< 8.3.3affected
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2026-9735

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Keyfile contents are in MongoDB Server logs
Source: CVE Program / CVE List V5
Vulnerability Description
MongoDB server may log authentication parameters, including credentials, to the server log during SASL authentication. When connection health metric logging is enabled, the full authentication parameters are written to the log without redaction.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Source: CVE Program / CVE List V5
Vulnerability Type
通过日志文件的信息暴露
Source: CVE Program / CVE List V5
Vulnerability Title
MongoDB Server 日志信息泄露漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
MongoDB Server是美国MongoDB公司的一套开源的NoSQL数据库。该数据库提供面向集合的存储、动态查询、数据复制及自动故障转移等功能。 MongoDB Server存在日志信息泄露漏洞,该漏洞源于SASL身份验证期间可能将认证参数包括凭据记录到服务器日志,且启用连接健康指标日志记录时未对完整认证参数进行脱敏处理。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
MongoDBMongoDB Server 8.3.0 ~ 8.3.3 -

II. Public POCs for CVE-2026-9735

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-9735

登录查看更多情报信息。

Same Patch Batch · MongoDB · 2026-06-09 · 14 CVEs total

CVE-2026-97538.1 HIGHServer crash via malformed binary diff passed to $_internalApplyOplogUpdate.
CVE-2026-97407.5 HIGHUnbounded recursion in BSONColumn interleaved-reference causes pre-auth stack overflow
CVE-2026-97427.5 HIGHAuthenticate command with specific mechanism parameter can trigger server crash
CVE-2026-97506.5 MEDIUMMetadata name collision on $-prefixed fields causes post-auth server crash
CVE-2026-97486.5 MEDIUM$_internalConvertBucketIndexStats may crash the mongod server when working on no timeserie
CVE-2026-97476.5 MEDIUMCrafted cross-shard merge aggregation crashes MongoDB Server
CVE-2026-97416.5 MEDIUMClient side encryption fails to encrypt values in a $vectorSearch
CVE-2026-97496.5 MEDIUMUsing MaxKey() may crash the server
CVE-2026-97526.5 MEDIUMGeometryCollection with strict-winding polygon causes server crash during 2dsphere index k
CVE-2026-97466.5 MEDIUMServer crashes in case of the use of exchange
CVE-2026-97436.5 MEDIUMAggregation sub-pipeline null dereference may allow DoS via crafted getMore
CVE-2026-97546.5 MEDIUMStack memory disclosure in filemd5 command
CVE-2026-97515.5 MEDIUMSensitive data could be written to mongod.log