CVE-2020-16216— Philips Patient Monitoring Devices Improper Input Validation

Quick assessment

Affected
Philips IntelliVue patient monitors
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Philips Patient Information Center iX是欧洲飞利浦(Philips)公司的飞利浦患者信息中心 (PIC iX) 是我们患者监测系统的核心,它有助于了解患者状况,帮助护理人员及早识别潜在的恶化,同时增强临床工作流程。 Philips Patient Information Center iX 中存在输入验证错误漏洞。该漏洞源于在电子表格软件打开文件时可能解释为命令的特殊元素。以下是受影响的产品及版本:B.02, C.02, C.03。

AI Predicted 7.5 Difficulty: Moderate EPSS 0.70% · P51
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2020-16216

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Philips Patient Monitoring Devices Improper Input Validation
Source: CVE Program / CVE List V5
Vulnerability Description
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
输入验证不恰当
Source: CVE Program / CVE List V5
Vulnerability Title
Philips Patient Information Center iX 输入验证错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Philips Patient Information Center iX是欧洲飞利浦(Philips)公司的飞利浦患者信息中心 (PIC iX) 是我们患者监测系统的核心,它有助于了解患者状况,帮助护理人员及早识别潜在的恶化,同时增强临床工作流程。 Philips Patient Information Center iX 中存在输入验证错误漏洞。该漏洞源于在电子表格软件打开文件时可能解释为命令的特殊元素。以下是受影响的产品及版本:B.02, C.02, C.03。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Philips IntelliVue patient monitors MX100 -
Philips IntelliVue X2 -

II. Public POCs for CVE-2020-16216

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2020-16216

请登录查看更多情报信息。

Vendor Advisories for CVE-2020-16216 (1)

Same Patch Batch · Philips · 2020-09-11 · 8 CVEs total

CVE-2020-16212 Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere
CVE-2020-16214 Philips Patient Monitoring Devices Improper Neutralization of Formula Elements in a CSV Fi
CVE-2020-16218 Philips Patient Monitoring Devices Cross-site Scripting
CVE-2020-16220 Philips Patient Monitoring Devices Improper Validation of Syntactic Correctness of Input
CVE-2020-16222 Philips Patient Monitoring Devices Improper Authentication
CVE-2020-16224 Philips Patient Monitoring Devices Improper Handling of Length Parameter Inconsistency
CVE-2020-16228 Philips Patient Monitoring Devices Improper Check for Certificate Revocation

IV. Related Vulnerabilities