Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2020-7479

Quick assessment

Affected
n/a IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009)
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Schneider Electric Interactive Graphical SCADA System(IGSS)是法国施耐德电气(Schneider Electric)公司的一套用于监控和控制工业过程的SCADA(数据采集与监控系统)系统。 Schneider Electric IGSS 14及之前版本(使用IGSSupdate服务)中存在访问控制错误漏洞。本地攻击者可利用该漏洞执行权限较高的进程。

AI Predicted 5.4 Difficulty: Easy EPSS 0.51% · P42

Possible ATT&CK Techniques 1 AI

T1068 · Exploitation for Privilege Escalation
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2020-7479

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
关键功能的认证机制缺失
Source: CVE Program / CVE List V5
Vulnerability Title
Schneider Electric Interactive Graphical SCADA System 访问控制错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric Interactive Graphical SCADA System(IGSS)是法国施耐德电气(Schneider Electric)公司的一套用于监控和控制工业过程的SCADA(数据采集与监控系统)系统。 Schneider Electric IGSS 14及之前版本(使用IGSSupdate服务)中存在访问控制错误漏洞。本地攻击者可利用该漏洞执行权限较高的进程。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
- IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009) IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate) -

II. Public POCs for CVE-2020-7479

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2020-7479

登录查看更多情报信息。

Vendor Advisories for CVE-2020-7479 (1)

Other References for CVE-2020-7479 (1)

Same Patch Batch · n/a · 2020-03-23 · 44 CVEs total

CVE-2020-9759 4.6 MEDIUM webOS TV Emulator privilege escalation vulnerability
CVE-2016-11022 NETGEAR Prosafe WC9500、WC7600和WC7520 操作系统命令注入漏洞
CVE-2020-1951 Apache Tika 安全漏洞
CVE-2019-19964 NETGEAR GS728TPS 授权问题漏洞
CVE-2019-5185 WAGO PFC 200 缓冲区错误漏洞
CVE-2019-15510 ZOHO ManageEngine Desktop Central 注入漏洞
CVE-2020-10661 HashiCorp Vault 安全漏洞
CVE-2020-10660 HashiCorp Vault 安全漏洞
CVE-2020-10593 Tor 安全漏洞
CVE-2020-10592 Tor 资源管理错误漏洞
CVE-2019-5186 WAGO PFC 200 缓冲区错误漏洞
CVE-2020-10793 CodeIgniter 安全漏洞
CVE-2020-8497 Artica Pandora FMS 信息泄露漏洞
CVE-2020-7935 Artica Pandora FMS 代码问题漏洞
CVE-2020-8511 Artica Pandora FMS 代码问题漏洞
CVE-2020-9760 WeeChat 缓冲区错误漏洞
CVE-2020-10364 MikroTik routers 资源管理错误漏洞
CVE-2020-8838 ZOHO ManageEngine AssetExplorer 安全漏洞
CVE-2019-19034 ZOHO ManageEngine Asset Explor 操作系统命令注入漏洞
CVE-2019-20626 Honda HR-V 2017 安全漏洞

Showing top 20 of 44 CVEs. View all on vendor page → →

IV. Related Vulnerabilities

V. Comments for CVE-2020-7479

No comments yet


Leave a comment