Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2021-22823

Quick assessment

Affected
n/a Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
Exploitation
High exploitation probability; assess promptly
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Schneider Electric Interactive Graphical SCADA System(IGSS)是法国施耐德电气(Schneider Electric)公司的一套用于监控和控制工业过程的SCADA(数据采集与监控系统)系统。 Schneider Electric Interactive Graphical SCADA System Data Collector (dc.exe)存在访问控制错误漏洞,该漏洞源于缺少对关键功能的身份验证,由于缺乏对网络消息的验证,该漏洞可能导致在运行 I

AI Predicted 6.5 Difficulty: Easy EPSS 21.39% · P97
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2021-22823

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
关键功能的认证机制缺失
Source: CVE Program / CVE List V5
Vulnerability Title
Schneider Electric Interactive Graphical SCADA System访问控制错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric Interactive Graphical SCADA System(IGSS)是法国施耐德电气(Schneider Electric)公司的一套用于监控和控制工业过程的SCADA(数据采集与监控系统)系统。 Schneider Electric Interactive Graphical SCADA System Data Collector (dc.exe)存在访问控制错误漏洞,该漏洞源于缺少对关键功能的身份验证,由于缺乏对网络消息的验证,该漏洞可能导致在运行 I
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
- Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) -

II. Public POCs for CVE-2021-22823

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2021-22823

登录查看更多情报信息。

Other References for CVE-2021-22823 (1)

Same Patch Batch · n/a · 2022-02-11 · 68 CVEs total

CVE-2021-23555 9.8 CRITICAL Sandbox Bypass
CVE-2021-23597 7.5 HIGH Denial of Service (DoS)
CVE-2021-22785 Schneider Electric 多款产品信息泄露漏洞
CVE-2021-45387 AppNeta tcpreplay 安全漏洞
CVE-2021-45386 Appneta Tcpreplay 安全漏洞
CVE-2021-45385 ffjpeg 代码问题漏洞
CVE-2021-42940 Projeqtor 安全漏洞
CVE-2021-44111 S-cart 路径遍历漏洞
CVE-2021-31932 Nokia BTS TRS web console 安全漏洞
CVE-2021-22748 Schneider Electric C-Bus Toolkit 路径遍历漏洞
CVE-2021-22796 Schneider Electric 多款产品授权问题漏洞
CVE-2020-36062 PHPGurukul Dairy Farm Shop Management System 信任管理问题漏洞
CVE-2021-22787 Schneider Electric Modicon M340 输入验证错误漏洞
CVE-2021-22798 Schneider Electric Conext™ComBox 安全漏洞
CVE-2021-22788 Schneider Electric 多款产品缓冲区错误漏洞
CVE-2021-22806 Schneider Electric 多款产品安全漏洞
CVE-2021-22801 Schneider Electric ConneXium Network Manager Software 安全漏洞
CVE-2021-22803 Schneider Electric IGSS 代码问题漏洞
CVE-2021-22802 Schneider Electric IGSS 安全漏洞
CVE-2021-22804 Schneider Electric IGSS 路径遍历漏洞

Showing top 20 of 68 CVEs. View all on vendor page → →

IV. Related Vulnerabilities

V. Comments for CVE-2021-22823

No comments yet


Leave a comment