Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2021-32966— Philips Interoperability Solution XDS - Clear Text Transmission of Sensitive Information

Quick assessment

Affected
Philips Interoperability Solution XDS
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Philips Interoperability Solution XDS是欧洲飞利浦(Philips)公司的一个解决方案。提供了一个基于开放标准的平台,支持所有类型的医学图像和临床信息。 Philips Interoperability Solution XDS存在安全漏洞,该漏洞源于。该漏洞存在的原因是,当配置为通过TLS使用LDAP时,软件使用不安全的通信通道传输敏感信息,并且域控制器返回LDAP引用。具有拦截网络通信能力的远程攻击者可利用该漏洞可以远程读取LDAP系统凭据。该漏洞允许远程攻击者可利

CVSS 3.7 · Low EPSS 0.47% · P38
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2021-32966

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Philips Interoperability Solution XDS - Clear Text Transmission of Sensitive Information
Source: CVE Program / CVE List V5
Vulnerability Description
Philips Interoperability Solution XDS versions 2.5 through 3.11 and 2018-1 through 2021-1 are vulnerable to clear text transmission of sensitive information when configured to use LDAP via TLS and where the domain controller returns LDAP referrals, which may allow an attacker to remotely read LDAP system credentials.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N
Source: CVE Program / CVE List V5
Vulnerability Type
敏感数据的明文传输
Source: CVE Program / CVE List V5
Vulnerability Title
Philips Interoperability Solution XDS 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Philips Interoperability Solution XDS是欧洲飞利浦(Philips)公司的一个解决方案。提供了一个基于开放标准的平台,支持所有类型的医学图像和临床信息。 Philips Interoperability Solution XDS存在安全漏洞,该漏洞源于。该漏洞存在的原因是,当配置为通过TLS使用LDAP时,软件使用不安全的通信通道传输敏感信息,并且域控制器返回LDAP引用。具有拦截网络通信能力的远程攻击者可利用该漏洞可以远程读取LDAP系统凭据。该漏洞允许远程攻击者可利
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Philips Interoperability Solution XDS 2.5 through 3.11 -

II. Public POCs for CVE-2021-32966

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2021-32966

请登录查看更多情报信息。

Vendor Advisories for CVE-2021-32966 (1)

IV. Related Vulnerabilities

V. Comments for CVE-2021-32966

No comments yet