CVE-2023-31129— Contiki-NG missing NULL pointer check in IPv6 neighbor discovery

Quick assessment

Affected
contiki-ng contiki-ng
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Contiki-NG是一套用于下一代IoT(物联网)设备的开源跨平台操作系统。 Contiki-NG 4.8及之前版本存在代码问题漏洞,该漏洞源于消息处理程序不会检查带有 SLLAO 的 RS 消息,SLLAO 指示链路层地址更改,实际上可以为指示的地址创建邻居条目,结果指针在没有检查的情况下使用,导致取消引用类型为 uip_ds6_nbr_t 的 NULL 指针。

CVSS 7.5 · High EPSS 0.64% · P48

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2023-31129

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Contiki-NG missing NULL pointer check in IPv6 neighbor discovery
Source: CVE Program / CVE List V5
Vulnerability Description
The Contiki-NG operating system versions 4.8 and prior can be triggered to dereference a NULL pointer in the message handling code for IPv6 router solicitiations. Contiki-NG contains an implementation of IPv6 Neighbor Discovery (ND) in the module `os/net/ipv6/uip-nd6.c`. The ND protocol includes a message type called Router Solicitation (RS), which is used to locate routers and update their address information via the SLLAO (Source Link-Layer Address Option). If the indicated source address changes, a given neighbor entry is set to the STALE state. The message handler does not check for RS messages with an SLLAO that indicates a link-layer address change that a neighbor entry can actually be created for the indicated address. The resulting pointer is used without a check, leading to the dereference of a NULL pointer of type `uip_ds6_nbr_t`. The problem has been patched in the `develop` branch of Contiki-NG, and will be included in the upcoming 4.9 release. As a workaround, users can apply Contiki-NG pull request #2271 to patch the problem directly.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Source: CVE Program / CVE List V5
Vulnerability Type
空指针解引用
Source: CVE Program / CVE List V5
Vulnerability Title
Contiki-NG 代码问题漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Contiki-NG是一套用于下一代IoT(物联网)设备的开源跨平台操作系统。 Contiki-NG 4.8及之前版本存在代码问题漏洞,该漏洞源于消息处理程序不会检查带有 SLLAO 的 RS 消息,SLLAO 指示链路层地址更改,实际上可以为指示的地址创建邻居条目,结果指针在没有检查的情况下使用,导致取消引用类型为 uip_ds6_nbr_t 的 NULL 指针。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
contiki-ng contiki-ng <= 4.8 -

II. Public POCs for CVE-2023-31129

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2023-31129

登录查看更多情报信息。

Vendor Advisories for CVE-2023-31129 (1)

IV. Related Vulnerabilities

V. Comments for CVE-2023-31129

No comments yet


Leave a comment