Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2023-51603— Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability

Quick assessment

Affected
Honeywell Saia PG5 Controls Suite
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Honeywell Saia PG5 Controls Suite是美国霍尼韦尔(Honeywell)公司的一款工业自动化和楼宇自动化的控制系统软件。 Honeywell Saia PG5 Controls Suite存在安全漏洞,该漏洞源于在使用用户提供的路径之前未对其进行正确验证。

AI Predicted 7.8 Difficulty: Moderate EPSS 1.57% · P75

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2023-51603

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability
Source: CVE Program / CVE List V5
Vulnerability Description
Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of CAB files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18592.
Source: CVE Program / CVE List V5
CVSS Information
N/A
Source: CVE Program / CVE List V5
Vulnerability Type
对路径名的限制不恰当(路径遍历)
Source: CVE Program / CVE List V5
Vulnerability Title
Honeywell Saia PG5 Controls Suite 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Honeywell Saia PG5 Controls Suite是美国霍尼韦尔(Honeywell)公司的一款工业自动化和楼宇自动化的控制系统软件。 Honeywell Saia PG5 Controls Suite存在安全漏洞,该漏洞源于在使用用户提供的路径之前未对其进行正确验证。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Honeywell Saia PG5 Controls Suite PG5 v2.3.193 -

II. Public POCs for CVE-2023-51603

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2023-51603

请登录查看更多情报信息。

Vendor Advisories for CVE-2023-51603 (1)

Same Patch Batch · Honeywell · 2024-05-03 · 7 CVEs total

CVE-2023-51602 Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vu
CVE-2023-51601 Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vu
CVE-2023-51605 Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vu
CVE-2023-51600 Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vu
CVE-2023-51599 Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability
CVE-2023-51604 Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vu

IV. Related Vulnerabilities

V. Comments for CVE-2023-51603

No comments yet


Leave a comment