I. Basic Information for CVE-2026-4272
Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
CVE-2026-4272 - Bluetooth Remote Execution of System Commands Vulnerability
Source: NVD (National Vulnerability Database)
Vulnerability Description
Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA. This vulnerability could allow a remote attacker within Bluetooth range of the scanner's base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned  CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N
Source: NVD (National Vulnerability Database)
Vulnerability Type
关键功能的认证机制缺失
Source: NVD (National Vulnerability Database)
Vulnerability Title
Honeywell Handheld Scanners 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Honeywell Handheld Scanners是美国Honeywell公司的一个条形码扫描设备。 Honeywell Handheld Scanners存在安全漏洞,该漏洞源于缺少关键功能身份验证,可能导致远程攻击者在蓝牙范围内未经身份验证执行系统命令。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)
Affected Products
VendorProductAffected VersionsCPESubscribe
HoneywellBarcode Scanners C1 Base(Ingenic x1000) ~ GK000432BAA -
II. Public POCs for CVE-2026-4272
#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC
III. Intelligence Information for CVE-2026-4272
Please Login to view more intelligence information
IV. Related Vulnerabilities
V. Comments for CVE-2026-4272

No comments yet


Leave a comment