CVE-2024-8530

Quick assessment

Affected
Schneider Electric Data Center Expert
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Schneider Electric Data Center Expert是美国施耐德电气(Schneider Electric)公司的一款数据监控软件。 Schneider Electric Data Center Expert 8.1.1.3及之前版本存在访问控制错误漏洞,该漏洞源于关键功能身份验证缺失,当已生成的logcaptures存档直接通过 HTTPS 访问时,可能会导致私有数据泄露。

CVSS 5.9 · Medium EPSS 0.55% · P44

Possible ATT&CK Techniques 1 AI

T1530 · Data from Cloud Storage
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2024-8530

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause exposure of private data when an already generated “logcaptures” archive is accessed directly by HTTPS.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
Source: CVE Program / CVE List V5
Vulnerability Type
关键功能的认证机制缺失
Source: CVE Program / CVE List V5
Vulnerability Title
Schneider Electric Data Center Expert 访问控制错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric Data Center Expert是美国施耐德电气(Schneider Electric)公司的一款数据监控软件。 Schneider Electric Data Center Expert 8.1.1.3及之前版本存在访问控制错误漏洞,该漏洞源于关键功能身份验证缺失,当已生成的logcaptures存档直接通过 HTTPS 访问时,可能会导致私有数据泄露。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Schneider Electric Data Center Expert Versions 8.1.1.3 and prior -

II. Public POCs for CVE-2024-8530

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-8530

请登录查看更多情报信息。

Same Patch Batch · Schneider Electric · 2024-10-11 · 3 CVEs total

CVE-2024-9002 7.8 HIGH Schneider Electric Easergy Studio 安全漏洞
CVE-2024-8531 7.2 HIGH Schneider Electric Data Center Expert 数据伪造问题漏洞

IV. Related Vulnerabilities