Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%
Get alerts for future matching vulnerabilitiesLog in to subscribe
I. Basic Information for CVE-2025-14095
Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Privilege boundary violation in Radiometer Products
Source: NVD (National Vulnerability Database)
Vulnerability Description
A "Privilege boundary violation" vulnerability is identified affecting multiple Radiometer Products. Exploitation of this vulnerability gives a user with physical access to the analyzer, the possibility to gain unauthorized access to functionalities outside the restricted environment. The vulnerability is due to weakness in the design of access control implementation in application software.  Other related CVE's are CVE-2025-14096 & CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required configuration for Exposure: Physical access to the analyzer is needed. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided working proof-of-concept. Radiometer is not aware of any publicly available exploit at the time of publication.                                                                                                                                                                                        Note: CVSS score 6.8 when underlying OS is Windows 7 or Windows XP Operating systems and CVSS score 5.7 when underlying OS is Windows 8 or Windows 10 operating systems.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
访问控制不恰当
Source: NVD (National Vulnerability Database)
Vulnerability Title
Radiometer Products 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Radiometer Products是丹麦Radiometer公司的一系列医疗诊断仪器。 Radiometer Products存在安全漏洞,该漏洞源于应用软件访问控制实现设计存在弱点,可能导致物理访问者获得对受限环境外功能的未授权访问。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)
Affected Products
VendorProductAffected VersionsCPESubscribe
Radiometer Medical ApsABL90 FLEX and ABL90 FLEX PLUS Analyzers All application software versions with Windows 7, Windows XP as underlying OS -
Radiometer Medical ApsAQT90 FLEX Analyzers All Application software versions <= 8.13 MR2 -
Radiometer Medical ApsABL800 BASIC and ABL800 FLEX Analyzers Application software versions < 6.20 MR2 with Windows 7, Windows XP as underlying OS -
Radiometer Medical ApsABL9 Analyzers Application software versions < 1.5.0 -
II. Public POCs for CVE-2025-14095
#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC
III. Intelligence Information for CVE-2025-14095
Please Login to view more intelligence information
IV. Related Vulnerabilities
V. Comments for CVE-2025-14095

No comments yet


Leave a comment