Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2025-15620— HiOS Switch Platform Denial-of-Service via Web Interface

Quick assessment

Affected
Belden Hirschmann HiOS Switch Platform
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Belden Hirschmann HiOS Switch Platform是美国Belden公司的一款工业以太网交换机操作系统平台。 Belden Hirschmann HiOS Switch Platform 09.4.05之前版本和10.3.01存在安全漏洞,该漏洞源于Web接口存在拒绝服务漏洞,可能导致远程攻击者通过向特定端点发送恶意HTTP GET请求来重启受影响设备。

CVSS 8.6 · High EPSS 0.51% · P42

Possible ATT&CK Techniques 1 AI

T1499 · Endpoint Denial of Service

Affected Version Matrix 2

VendorProduct Version RangeStatus
Belden Hirschmann HiOS Switch Platform 09.1.00≤ 09.4.05 affected
10.0.00≤ 10.3.01 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-15620

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
HiOS Switch Platform Denial-of-Service via Web Interface
Source: CVE Program / CVE List V5
Vulnerability Description
HiOS Switch Platform versions 09.1.00 through 09.4.04 and 10.0.00 through 10.3.00 contain a denial-of-service vulnerability in the web interface that allows remote attackers to reboot the affected device by sending a malicious HTTP GET request to a specific endpoint. Attackers can trigger an uncontrolled reboot condition through crafted HTTP requests to cause service disruption and unavailability of the switch.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
关键功能的认证机制缺失
Source: CVE Program / CVE List V5
Vulnerability Title
Belden Hirschmann HiOS Switch Platform 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Belden Hirschmann HiOS Switch Platform是美国Belden公司的一款工业以太网交换机操作系统平台。 Belden Hirschmann HiOS Switch Platform 09.4.05之前版本和10.3.01存在安全漏洞,该漏洞源于Web接口存在拒绝服务漏洞,可能导致远程攻击者通过向特定端点发送恶意HTTP GET请求来重启受影响设备。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Shenlong Deep Dive — AI Deep Analysis

10-question deep dive: root cause, exploitation, mitigation, urgency. Read summary free, full version requires login.

Affected Products

Vendor Product Affected Versions CPE Subscribe
Belden Hirschmann HiOS Switch Platform 09.1.00 ~ 09.4.05 -

II. Public POCs for CVE-2025-15620

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-15620

请登录查看更多情报信息。

Same Patch Batch · Belden · 2026-04-02 · 6 CVEs total

CVE-2024-14034 9.8 CRITICAL Hirschmann HiEOS Authentication Bypass via HTTP Management Module
CVE-2023-7342 8.8 HIGH Belden HiSecOS Web Server Privilege Escalation
CVE-2023-7343 7.8 HIGH Belden Industrial HiVision Arbitrary Code Execution via Malicious Project File
CVE-2024-14033 7.5 HIGH Hirschmann EagleSDV Denial of Service via TLS
CVE-2022-4986 7.5 HIGH Hirschmann EagleSDV Denial of Service via TLS

IV. Related Vulnerabilities

V. Comments for CVE-2025-15620

No comments yet


Leave a comment