CVE-2025-2522— Lack of buffer clearing before reuse may result in incorrect system behavior.

Quick assessment

Affected
Honeywell C300 PCNT02
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Honeywell Experion Server是美国霍尼韦尔(Honeywell)公司的一款高性能工业控制系统服务器,主要用于 Experion Process Knowledge System(PKS)平台。 Honeywell Experion Server PKS 520.1至520.2 TCU9 HF1和530至530 TCU3版本和OneWireless WDM 322.1至322.4和330.1至330.3版本存在安全漏洞,该漏洞源于资源中敏感信息暴露,可能导致系统行为异常。

CVSS 6.5 · Medium EPSS 0.25% · P15

Possible ATT&CK Techniques 1 AI

T1557 · Adversary-in-the-Middle
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-2522

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Lack of buffer clearing before reuse may result in incorrect system behavior.
Source: CVE Program / CVE List V5
Vulnerability Description
The Honeywell Experion PKS and OneWireless WDM contains Sensitive Information in Resource vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could result in buffer reuse which may cause incorrect system behavior. Honeywell also recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.  The affected Experion PKS products are C300, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are 520.1 before 520.2 TCU9 HF1 and 530 before 530 TCU3. The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
Source: CVE Program / CVE List V5
Vulnerability Type
在释放前未清除敏感信息
Source: CVE Program / CVE List V5
Vulnerability Title
Honeywell Experion Server 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Honeywell Experion Server是美国霍尼韦尔(Honeywell)公司的一款高性能工业控制系统服务器,主要用于 Experion Process Knowledge System(PKS)平台。 Honeywell Experion Server PKS 520.1至520.2 TCU9 HF1和530至530 TCU3版本和OneWireless WDM 322.1至322.4和330.1至330.3版本存在安全漏洞,该漏洞源于资源中敏感信息暴露,可能导致系统行为异常。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Honeywell C300 PCNT02 520.1 ~ 520.2 TCU9 -
Honeywell C300 PCNT05 520.1 ~ 520.2 TCU9 -
Honeywell FIM4 520.1 ~ 520.2 TCU9 -
Honeywell FIM8 520.1 ~ 520.2 TCU9 -
Honeywell UOC 520.1 ~ 520.2 TCU9 -
Honeywell CN100 520.1 ~ 520.2 TCU9 -
Honeywell HCA 520.1 ~ 520.2 TCU9 -
Honeywell C300PM 520.1 ~ 520.2 TCU9 -
Honeywell C200E 520.1 ~ 520.2 TCU9 -
Honeywell Wireless Device Manager 322.1 ~ 322.4 -

II. Public POCs for CVE-2025-2522

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-2522

请登录查看更多情报信息。

Vendor Pages for CVE-2025-2522 (1)

Same Patch Batch · Honeywell · 2025-07-10 · 6 CVEs total

CVE-2025-2523 9.4 CRITICAL Lack of buffer clearing before reuse may result in incorrect system behavior.
CVE-2025-2521 8.6 HIGH Lack of indexes’ validation against buffer borders leads to remote code execution.
CVE-2025-3947 8.2 HIGH Integer underflow during processing of short network packets in CDA FTEB responder
CVE-2025-3946 8.2 HIGH Incorrect response generation during FTEB protocol processing
CVE-2025-2520 7.5 HIGH Dereferencing of an uninitialized pointer leads to denial of service.

IV. Related Vulnerabilities

V. Comments for CVE-2025-2522

No comments yet


Leave a comment