Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2025-31354— Subnet Solutions PowerSYSTEM Center Out-of-Bounds Read

Quick assessment

Affected
Subnet Solutions PowerSYSTEM Center 2020
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Subnet Solutions PowerSYSTEM Center是Subnet Solutions公司的一个电力解决方案。 Subnet Solutions PowerSYSTEM Center存在缓冲区错误漏洞,该漏洞源于导入特制EC证书可能导致CPU消耗过高。

CVSS 4.3 · Medium EPSS 0.13% · P3

Possible ATT&CK Techniques 1 AI

T1496 · Resource Hijacking
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-31354

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Subnet Solutions PowerSYSTEM Center Out-of-Bounds Read
Source: CVE Program / CVE List V5
Vulnerability Description
Subnet Solutions PowerSYSTEM Center's SMTPS notification service can be affected by importing an EC certificate with crafted F2m parameters, which can lead to excessive CPU consumption during the evaluation of the curve parameters.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
Source: CVE Program / CVE List V5
Vulnerability Type
跨界内存读
Source: CVE Program / CVE List V5
Vulnerability Title
Subnet Solutions PowerSYSTEM Center 缓冲区错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Subnet Solutions PowerSYSTEM Center是Subnet Solutions公司的一个电力解决方案。 Subnet Solutions PowerSYSTEM Center存在缓冲区错误漏洞,该漏洞源于导入特制EC证书可能导致CPU消耗过高。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Subnet Solutions PowerSYSTEM Center 2020 0 ~ 5.24.x -

II. Public POCs for CVE-2025-31354

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-31354

登录查看更多情报信息。

Vendor Advisories for CVE-2025-31354 (1)

IV. Related Vulnerabilities