Affected
Mitsubishi Electric Corporation G-50
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Mitsubishi Electric G-50等都是日本三菱电机(Mitsubishi Electric)公司的一款空调集中控制器。 Mitsubishi Electric多款产品存在访问控制错误漏洞,该漏洞源于缺少关键功能身份验证,可能导致非法控制空调系统或信息泄露。以下产品和版本受到影响:G-50 3.37及之前版本、G-50-W 3.37及之前版本、G-50A 3.37及之前版本、GB-50 3.37及之前版本、GB-50A 3.37及之前版本、GB-24A 9.12及之前版本、G-150AD 3

CVSS 9.8 · Critical EPSS 1.12% · P65
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-3699

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
关键功能的认证机制缺失
Source: CVE Program / CVE List V5
Vulnerability Title
Mitsubishi Electric多款产品 访问控制错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Mitsubishi Electric G-50等都是日本三菱电机(Mitsubishi Electric)公司的一款空调集中控制器。 Mitsubishi Electric多款产品存在访问控制错误漏洞,该漏洞源于缺少关键功能身份验证,可能导致非法控制空调系统或信息泄露。以下产品和版本受到影响:G-50 3.37及之前版本、G-50-W 3.37及之前版本、G-50A 3.37及之前版本、GB-50 3.37及之前版本、GB-50A 3.37及之前版本、GB-24A 9.12及之前版本、G-150AD 3
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Shenlong Deep Dive — AI Deep Analysis

10-question deep dive: root cause, exploitation, mitigation, urgency. Read summary free, full version requires login.

Affected Products

Vendor Product Affected Versions CPE Subscribe
Mitsubishi Electric Corporation G-50 All versions -
Mitsubishi Electric Corporation G-50-W All versions -
Mitsubishi Electric Corporation G-50A All versions -
Mitsubishi Electric Corporation GB-50 All versions -
Mitsubishi Electric Corporation GB-50A All versions -
Mitsubishi Electric Corporation GB-24A All versions -
Mitsubishi Electric Corporation G-150AD All versions -
Mitsubishi Electric Corporation AG-150A-A All versions -
Mitsubishi Electric Corporation AG-150A-J All versions -
Mitsubishi Electric Corporation GB-50AD All versions -
Mitsubishi Electric Corporation GB-50ADA-A All versions -
Mitsubishi Electric Corporation GB-50ADA-J All versions -
Mitsubishi Electric Corporation EB-50GU-A All versions -
Mitsubishi Electric Corporation EB-50GU-J All versions -
Mitsubishi Electric Corporation AE-200J All versions -
Mitsubishi Electric Corporation AE-200A All versions -
Mitsubishi Electric Corporation AE-200E All versions -
Mitsubishi Electric Corporation AE-50J All versions -
Mitsubishi Electric Corporation AE-50A All versions -
Mitsubishi Electric Corporation AE-50E All versions -
Mitsubishi Electric Corporation EW-50J All versions -
Mitsubishi Electric Corporation EW-50A All versions -
Mitsubishi Electric Corporation EW-50E All versions -
Mitsubishi Electric Corporation TE-200A All versions -
Mitsubishi Electric Corporation TE-50A All versions -
Mitsubishi Electric Corporation TW-50A All versions -
Mitsubishi Electric Corporation CMS-RMD-J All versions -

II. Public POCs for CVE-2025-3699

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-3699

请登录查看更多情报信息。

Vendor Advisories for CVE-2025-3699 (2)

IV. Related Vulnerabilities

V. Comments for CVE-2025-3699

No comments yet


Leave a comment