Affected
Siemens IE/PB LINK HA
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Siemens RUGGEDCOM RM1224是德国西门子(Siemens)公司的一个无线路由器。提供往返远程位置的数据通信,可提供4G LTE连接并自动回退到3G UMTS或EVDO蜂窝网络。 Siemens多款产品存在代码问题漏洞,该漏洞源于处理特制IPv4请求时存在空指针取消引用,可能导致拒绝服务。以下产品受到影响:IE/PB LINK HA、IE/PB link PN IO、RUGGEDCOM RM1224 LTE(4G) EU等。

CVSS 7.5 · High EPSS 0.32% · P23

Possible ATT&CK Techniques 1 AI

T1499 · Endpoint Denial of Service

Affected Version Matrix 305

VendorProduct Version RangeStatus
Siemens IE/PB LINK HA < V4.1.2 affected
Siemens IE/PB link PN IO < * affected
Siemens RUGGEDCOM RM1224 LTE(4G) EU < V8.3 affected
Siemens RUGGEDCOM RM1224 LTE(4G) NAM < V8.3 affected
Siemens SCALANCE M804PB < V8.3 affected
Siemens SCALANCE M812-1 ADSL-Router < V8.3 affected
< V8.3 affected
Siemens SCALANCE M816-1 ADSL-Router < V8.3 affected
< V8.3 affected
Siemens SCALANCE M826-2 SHDSL-Router < V8.3 affected
Siemens SCALANCE M874-2 < V8.3 affected
Siemens SCALANCE M874-3 < V8.3 affected
Siemens SCALANCE M874-3 3G-Router (CN) < V8.3 affected
Siemens SCALANCE M876-3 < V8.3 affected
Siemens SCALANCE M876-3 (ROK) < V8.3 affected
Siemens SCALANCE M876-4 < V8.3 affected
Siemens SCALANCE M876-4 (EU) < V8.3 affected
Siemens SCALANCE M876-4 (NAM) < V8.3 affected
Siemens SCALANCE MUB852-1 (A1) < V8.3 affected
Siemens SCALANCE MUB852-1 (B1) < V8.3 affected
Siemens SCALANCE MUM853-1 (A1) < V8.3 affected
Siemens SCALANCE MUM853-1 (B1) < V8.3 affected
Siemens SCALANCE MUM853-1 (EU) < V8.3 affected
Siemens SCALANCE MUM856-1 (A1) < V8.3 affected
Siemens SCALANCE MUM856-1 (B1) < V8.3 affected
Siemens SCALANCE MUM856-1 (CN) < V8.3 affected
Siemens SCALANCE MUM856-1 (EU) < V8.3 affected
Siemens SCALANCE MUM856-1 (RoW) < V8.3 affected
Siemens SCALANCE S615 EEC LAN-Router < V8.3 affected
Siemens SCALANCE S615 LAN-Router < V8.3 affected
Siemens SCALANCE SC622-2C < V3.2 affected
Siemens SCALANCE SC626-2C < V3.2 affected
Siemens SCALANCE SC632-2C < V3.2 affected
Siemens SCALANCE SC636-2C < V3.2 affected
Siemens SCALANCE SC642-2C < V3.2 affected
Siemens SCALANCE SC646-2C < V3.2 affected
Siemens SCALANCE W1748-1 M12 < * affected
< * affected
Siemens SCALANCE W1788-1 M12 < * affected
Siemens SCALANCE W1788-2 EEC M12 < * affected
Siemens SCALANCE W1788-2 M12 < * affected
Siemens SCALANCE W1788-2IA M12 < * affected
Siemens SCALANCE W721-1 RJ45 < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W722-1 RJ45 < V6.6.0 affected
< V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W734-1 RJ45 < V6.6.0 affected
< V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W734-1 RJ45 (USA) < V6.6.0 affected
Siemens SCALANCE W738-1 M12 < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W748-1 M12 < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W748-1 RJ45 < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W761-1 RJ45 < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W774-1 M12 EEC < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W774-1 RJ45 < V6.6.0 affected
< V6.6.0 affected
< V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W774-1 RJ45 (USA) < V6.6.0 affected
Siemens SCALANCE W778-1 M12 < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W778-1 M12 EEC < V6.6.0 affected
Siemens SCALANCE W778-1 M12 EEC (USA) < V6.6.0 affected
Siemens SCALANCE W786-1 RJ45 < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W786-2 RJ45 < V6.6.0 affected
< V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W786-2 SFP < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W786-2IA RJ45 < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W788-1 M12 < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W788-1 RJ45 < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W788-2 M12 < V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W788-2 M12 EEC < V6.6.0 affected
< V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE W788-2 RJ45 < V6.6.0 affected
< V6.6.0 affected
< V6.6.0 affected
Siemens SCALANCE WAB762-1 < V3.2.0 affected
Siemens SCALANCE WAM763-1 < V3.2.0 affected
Siemens SCALANCE WAM763-1 (ME) < V3.2.0 affected
Siemens SCALANCE WAM763-1 (US) < V3.2.0 affected
Siemens SCALANCE WAM766-1 < V3.2.0 affected
Siemens SCALANCE WAM766-1 (ME) < V3.2.0 affected
Siemens SCALANCE WAM766-1 (US) < V3.2.0 affected
Siemens SCALANCE WAM766-1 EEC < V3.2.0 affected
Siemens SCALANCE WAM766-1 EEC (ME) < V3.2.0 affected
Siemens SCALANCE WAM766-1 EEC (US) < V3.2.0 affected
Siemens SCALANCE WUB762-1 < V3.2.0 affected
Siemens SCALANCE WUB762-1 iFeatures < V3.2.0 affected
Siemens SCALANCE WUM763-1 < V3.2.0 affected
< V3.2.0 affected
Siemens SCALANCE WUM763-1 (US) < V3.2.0 affected
< V3.2.0 affected
Siemens SCALANCE WUM766-1 < V3.2.0 affected
Siemens SCALANCE WUM766-1 (ME) < V3.2.0 affected
Siemens SCALANCE WUM766-1 (USA) < V3.2.0 affected
Siemens SCALANCE X204-2 < * affected
Siemens SCALANCE X204-2FM < * affected
Siemens SCALANCE X204-2LD < * affected
Siemens SCALANCE X204-2LD TS < * affected
Siemens SCALANCE X204-2TS < * affected
Siemens SCALANCE X206-1 < * affected
Siemens SCALANCE X206-1LD < * affected
Siemens SCALANCE X208 < * affected
Siemens SCALANCE X208PRO < * affected
Siemens SCALANCE X212-2 < * affected
Siemens SCALANCE X212-2LD < * affected
Siemens SCALANCE X216 < * affected
Siemens SCALANCE X224 < * affected
Siemens SCALANCE X302-7 EEC (230V, coated) < * affected
Siemens SCALANCE X302-7 EEC (230V) < * affected
Siemens SCALANCE X302-7 EEC (24V, coated) < * affected
Siemens SCALANCE X302-7 EEC (24V) < * affected
Siemens SCALANCE X302-7 EEC (2x 230V, coated) < * affected
Siemens SCALANCE X302-7 EEC (2x 230V) < * affected
Siemens SCALANCE X302-7 EEC (2x 24V, coated) < * affected
Siemens SCALANCE X302-7 EEC (2x 24V) < * affected
Siemens SCALANCE X304-2FE < * affected
Siemens SCALANCE X306-1LD FE < * affected
Siemens SCALANCE X307-2 EEC (230V, coated) < * affected
Siemens SCALANCE X307-2 EEC (230V) < * affected
Siemens SCALANCE X307-2 EEC (24V, coated) < * affected
Siemens SCALANCE X307-2 EEC (24V) < * affected
Siemens SCALANCE X307-2 EEC (2x 230V, coated) < * affected
Siemens SCALANCE X307-2 EEC (2x 230V) < * affected
Siemens SCALANCE X307-2 EEC (2x 24V, coated) < * affected
Siemens SCALANCE X307-2 EEC (2x 24V) < * affected
Siemens SCALANCE X307-3 < * affected
< * affected
Siemens SCALANCE X307-3LD < * affected
< * affected
Siemens SCALANCE X308-2 < * affected
Siemens SCALANCE X308-2 RD (inkl. SIPLUS variants) < * affected
Siemens SCALANCE X308-2LD < * affected
< * affected
Siemens SCALANCE X308-2LH < * affected
< * affected
Siemens SCALANCE X308-2LH+ < * affected
< * affected
Siemens SCALANCE X308-2M < * affected
< * affected
Siemens SCALANCE X308-2M PoE < * affected
< * affected
Siemens SCALANCE X308-2M TS < * affected
< * affected
Siemens SCALANCE X310 < * affected
< * affected
Siemens SCALANCE X310FE < * affected
< * affected
Siemens SCALANCE X320-1 FE < * affected
Siemens SCALANCE X320-1-2LD FE < * affected
Siemens SCALANCE X408-2 < * affected
Siemens SCALANCE XF204 < * affected
Siemens SCALANCE XF204-2 < * affected
Siemens SCALANCE XF206-1 < * affected
Siemens SCALANCE XF208 < * affected
Siemens SCALANCE XM408-4C < * affected
Siemens SCALANCE XM408-4C (L3 int.) < * affected
Siemens SCALANCE XM408-8C < * affected
Siemens SCALANCE XM408-8C (L3 int.) < * affected
Siemens SCALANCE XM416-4C < * affected
Siemens SCALANCE XM416-4C (L3 int.) < * affected
Siemens SCALANCE XR324-12M (230V, ports on front) < * affected
< * affected
Siemens SCALANCE XR324-12M (230V, ports on rear) < * affected
< * affected
Siemens SCALANCE XR324-12M (24V, ports on front) < * affected
< * affected
Siemens SCALANCE XR324-12M (24V, ports on rear) < * affected
< * affected
Siemens SCALANCE XR324-12M TS (24V) < * affected
< * affected
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) < * affected
< * affected
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) < * affected
< * affected
Siemens SCALANCE XR324-4M EEC (24V, ports on front) < * affected
< * affected
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) < * affected
< * affected
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) < * affected
< * affected
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) < * affected
< * affected
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) < * affected
< * affected
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) < * affected
< * affected
Siemens SCALANCE XR324-4M PoE (230V, ports on front) < * affected
< * affected
Siemens SCALANCE XR324-4M PoE (230V, ports on rear) < * affected
< * affected
Siemens SCALANCE XR324-4M PoE (24V, ports on front) < * affected
< * affected
Siemens SCALANCE XR324-4M PoE (24V, ports on rear) < * affected
< * affected
Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) < * affected
< * affected
Siemens SCALANCE XR524-8C, 1x230V < * affected
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) < * affected
Siemens SCALANCE XR524-8C, 24V < * affected
Siemens SCALANCE XR524-8C, 24V (L3 int.) < * affected
Siemens SCALANCE XR524-8C, 2x230V < * affected
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) < * affected
Siemens SCALANCE XR526-8C, 1x230V < * affected
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) < * affected
Siemens SCALANCE XR526-8C, 24V < * affected
Siemens SCALANCE XR526-8C, 24V (L3 int.) < * affected
Siemens SCALANCE XR526-8C, 2x230V < * affected
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) < * affected
Siemens SCALANCE XR528-6M < * affected
Siemens SCALANCE XR528-6M (2HR2, L3 int.) < * affected
Siemens SCALANCE XR528-6M (2HR2) < * affected
Siemens SCALANCE XR528-6M (L3 int.) < * affected
Siemens SCALANCE XR552-12M < * affected
Siemens SCALANCE XR552-12M (2HR2, L3 int.) < * affected
Siemens SCALANCE XR552-12M (2HR2) < * affected
< * affected
Siemens SIMATIC CFU DIQ < V2.0.0 affected
Siemens SIMATIC CFU PA < V2.0.0 affected
< V2.0.0 affected
Siemens SIMATIC ET 200pro IM 154-8 PN/DP CPU < * affected
Siemens SIMATIC ET 200pro IM 154-8F PN/DP CPU < * affected
Siemens SIMATIC ET 200pro IM 154-8FX PN/DP CPU < * affected
Siemens SIMATIC ET 200S IM 151-8 PN/DP CPU < * affected
Siemens SIMATIC ET 200S IM 151-8F PN/DP CPU < * affected
Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN < * affected
Siemens SIMATIC ET 200SP CPU 1510SP-1 PN < * affected
Siemens SIMATIC ET 200SP CPU 1512SP F-1 PN < * affected
Siemens SIMATIC ET 200SP CPU 1512SP-1 PN < * affected
Siemens SIMATIC ET 200SP HA IM155-6 PN < V1.3 affected
Siemens SIMATIC S7-1500 CPU 1511-1 PN < * affected
Siemens SIMATIC S7-1500 CPU 1511F-1 PN < * affected
Siemens SIMATIC S7-1500 CPU 1513-1 PN < * affected
Siemens SIMATIC S7-1500 CPU 1515-2 PN < * affected
Siemens SIMATIC S7-1500 CPU 1515F-2 PN < * affected
Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP < * affected
Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP < * affected
Siemens SIMATIC S7-300 CPU 314C-2 PN/DP < * affected
Siemens SIMATIC S7-300 CPU 315-2 PN/DP < * affected
Siemens SIMATIC S7-300 CPU 315F-2 PN/DP < * affected
Siemens SIMATIC S7-300 CPU 315T-3 PN/DP < * affected
Siemens SIMATIC S7-300 CPU 317-2 PN/DP < * affected
Siemens SIMATIC S7-300 CPU 317F-2 PN/DP < * affected
Siemens SIMATIC S7-300 CPU 317T-3 PN/DP < * affected
Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP < * affected
Siemens SIMATIC S7-300 CPU 319-3 PN/DP < * affected
Siemens SIMATIC S7-300 CPU 319F-3 PN/DP < * affected
Siemens SIMATIC S7-400 CPU 412-2 PN V7 < * affected
Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 < * affected
Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7 < * affected
Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7 < * affected
Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7 < * affected
Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) < * affected
Siemens SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) < V10.2 affected
Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) < V8.3 affected
Siemens SIMIT UNIT V10 < * affected
Siemens SIMIT UNIT V11 < * affected
Siemens SINAMICS CBE20 < * affected
Siemens SINAMICS G115D < * affected
Siemens SINAMICS G120 (incl. SIPLUS variants) < * affected
Siemens SINAMICS G120C < * affected
Siemens SINAMICS G120D < * affected
Siemens SINAMICS G120X < * affected
Siemens SINAMICS G120XA < * affected
Siemens SINAMICS G130 < * affected
Siemens SINAMICS G150 < * affected
Siemens SINAMICS S110 < * affected
Siemens SINAMICS S120 (incl. SIPLUS variants) < * affected
Siemens SINAMICS S150 < * affected
Siemens SINUMERIK 840D sl < * affected
Siemens SIPLUS ET 200S IM 151-8 PN/DP CPU < * affected
Siemens SIPLUS ET 200S IM 151-8F PN/DP CPU < * affected
Siemens SIPLUS NET IE/PB link PN IO < * affected
Siemens SIPLUS S7-300 CPU 314C-2 PN/DP < * affected
Siemens SIPLUS S7-300 CPU 315-2 PN/DP < * affected
Siemens SIPLUS S7-300 CPU 315F-2 PN/DP < * affected
Siemens SIPLUS S7-300 CPU 317-2 PN/DP < * affected
Siemens SIPLUS S7-300 CPU 317F-2 PN/DP < * affected
Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7 < * affected
Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7 < * affected
Siemens SITOP PSU8600 1AC 20 A/4x5 A PN < * affected
Siemens SITOP PSU8600 3AC 20 A PN < * affected
Siemens SITOP PSU8600 3AC 20 A/4x5 A PN < * affected
Siemens SITOP PSU8600 3AC 40 A PN < * affected
Siemens SITOP PSU8600 3AC 40 A/4x10 A PN < * affected
Siemens SITOP PSU8600 3AC 40 A/4x10A EIP < * affected
Siemens SITOP UPS1600 10 A Ethernet/ PROFINET < * affected
Siemens SITOP UPS1600 20 A Ethernet/ PROFINET < * affected
Siemens SITOP UPS1600 40 A Ethernet/ PROFINET < * affected
Siemens SITOP UPS1600 EX 20 A Ethernet PROFINET < * affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-40833

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
The affected devices contain a null pointer dereference vulnerability while processing specially crafted IPv4 requests. This could allow an attacker to cause denial of service condition. A manual restart is required to recover the system.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
空指针解引用
Source: CVE Program / CVE List V5
Vulnerability Title
Siemens多款产品 代码问题漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens RUGGEDCOM RM1224是德国西门子(Siemens)公司的一个无线路由器。提供往返远程位置的数据通信,可提供4G LTE连接并自动回退到3G UMTS或EVDO蜂窝网络。 Siemens多款产品存在代码问题漏洞,该漏洞源于处理特制IPv4请求时存在空指针取消引用,可能导致拒绝服务。以下产品受到影响:IE/PB LINK HA、IE/PB link PN IO、RUGGEDCOM RM1224 LTE(4G) EU等。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Siemens IE/PB LINK HA 0 ~ V4.1.2 -
Siemens IE/PB link PN IO 0 ~ * -
Siemens RUGGEDCOM RM1224 LTE(4G) EU 0 ~ V8.3 -
Siemens RUGGEDCOM RM1224 LTE(4G) NAM 0 ~ V8.3 -
Siemens SCALANCE M804PB 0 ~ V8.3 -
Siemens SCALANCE M812-1 ADSL-Router 0 ~ V8.3 -
Siemens SCALANCE M812-1 ADSL-Router 0 ~ V8.3 -
Siemens SCALANCE M816-1 ADSL-Router 0 ~ V8.3 -
Siemens SCALANCE M816-1 ADSL-Router 0 ~ V8.3 -
Siemens SCALANCE M826-2 SHDSL-Router 0 ~ V8.3 -
Siemens SCALANCE M874-2 0 ~ V8.3 -
Siemens SCALANCE M874-3 0 ~ V8.3 -
Siemens SCALANCE M874-3 3G-Router (CN) 0 ~ V8.3 -
Siemens SCALANCE M876-3 0 ~ V8.3 -
Siemens SCALANCE M876-3 (ROK) 0 ~ V8.3 -
Siemens SCALANCE M876-4 0 ~ V8.3 -
Siemens SCALANCE M876-4 (EU) 0 ~ V8.3 -
Siemens SCALANCE M876-4 (NAM) 0 ~ V8.3 -
Siemens SCALANCE MUB852-1 (A1) 0 ~ V8.3 -
Siemens SCALANCE MUB852-1 (B1) 0 ~ V8.3 -
Siemens SCALANCE MUM853-1 (A1) 0 ~ V8.3 -
Siemens SCALANCE MUM853-1 (B1) 0 ~ V8.3 -
Siemens SCALANCE MUM853-1 (EU) 0 ~ V8.3 -
Siemens SCALANCE MUM856-1 (A1) 0 ~ V8.3 -
Siemens SCALANCE MUM856-1 (B1) 0 ~ V8.3 -
Siemens SCALANCE MUM856-1 (CN) 0 ~ V8.3 -
Siemens SCALANCE MUM856-1 (EU) 0 ~ V8.3 -
Siemens SCALANCE MUM856-1 (RoW) 0 ~ V8.3 -
Siemens SCALANCE S615 EEC LAN-Router 0 ~ V8.3 -
Siemens SCALANCE S615 LAN-Router 0 ~ V8.3 -

II. Public POCs for CVE-2025-40833

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-40833

请登录查看更多情报信息。

Vendor Advisories for CVE-2025-40833 (1)

Same Patch Batch · Siemens · 2026-05-12 · 20 CVEs total

CVE-2025-40949 9.1 CRITICAL Siemens多款产品 操作系统命令注入漏洞
CVE-2026-22924 9.1 CRITICAL Siemens SIMATIC CN 4100 访问控制错误漏洞
CVE-2026-25786 9.1 CRITICAL Siemens多款产品 跨站脚本漏洞
CVE-2026-25787 9.1 CRITICAL Siemens SIMATIC 跨站脚本漏洞
CVE-2026-41551 9.1 CRITICAL Siemens ROS# 安全漏洞
CVE-2025-40946 8.3 HIGH Siemens多款产品 安全漏洞
CVE-2025-12659 7.8 HIGH Heap-based buffer overflow in Siemens Simcenter Femap
CVE-2026-44412 7.8 HIGH Siemens Solid Edge 安全漏洞
CVE-2026-44411 7.8 HIGH Siemens Solid Edge 缓冲区错误漏洞
CVE-2026-27662 7.7 HIGH Siemens SIMATIC HMI Comfort Panels 安全漏洞
CVE-2025-40947 7.5 HIGH Siemens RUGGEDCOM 操作系统命令注入漏洞
CVE-2026-22925 7.5 HIGH Siemens SIMATIC CN 4100 安全漏洞
CVE-2026-33893 7.5 HIGH Siemens多款产品 信任管理问题漏洞
CVE-2026-33862 7.3 HIGH Siemens Teamcenter 跨站脚本漏洞
CVE-2026-25789 7.1 HIGH Siemens多款产品 跨站脚本漏洞
CVE-2025-40948 6.8 MEDIUM Siemens多款产品 参数注入漏洞
CVE-2026-41125 6.0 MEDIUM Siemens多款产品 SQL注入漏洞
CVE-2024-54017 5.3 MEDIUM Siemens SIPROTEC 5 安全漏洞
CVE-2026-42177 5.3 MEDIUM linux-entra-sso: PRT SSO cookie can leak to attacker-controlled hosts when broad host perm

IV. Related Vulnerabilities

V. Comments for CVE-2025-40833

No comments yet


Leave a comment