CVE-2025-52551— Proprietary protocol allows for unauthenticated file operations

Quick assessment

Affected
Copeland LP E2 Facility Management System
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Copeland E2 Facility Management Systems是美国Copeland公司的一款工业设备控制系统。 Copeland E2 Facility Management Systems存在安全漏洞,该漏洞源于专有协议处理不当,可能导致未授权文件操作。

AI Predicted 8.8 Difficulty: Easy EPSS 0.35% · P28

Possible ATT&CK Techniques 1 AI

T1564.004 · NTFS File Attributes
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-52551

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Proprietary protocol allows for unauthenticated file operations
Source: CVE Program / CVE List V5
Vulnerability Description
E2 Facility Management Systems use a proprietary protocol that allows for unauthenticated file operations on any file in the file system.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:L/SA:L
Source: CVE Program / CVE List V5
Vulnerability Type
关键功能的认证机制缺失
Source: CVE Program / CVE List V5
Vulnerability Title
Copeland E2 Facility Management Systems 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Copeland E2 Facility Management Systems是美国Copeland公司的一款工业设备控制系统。 Copeland E2 Facility Management Systems存在安全漏洞,该漏洞源于专有协议处理不当,可能导致未授权文件操作。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Copeland LP E2 Facility Management System 0 ~ <=4.11F02 -

II. Public POCs for CVE-2025-52551

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-52551

登录查看更多情报信息。

Same Patch Batch · Copeland LP · 2025-09-02 · 10 CVEs total

CVE-2025-6519 Consistent predictable generation of the password for the default admin user "ONEDAY" to t
CVE-2025-52547 DoS to the application services
CVE-2025-52550 Firmware upgrade packages are unsigned
CVE-2025-52544 Arbitrary read file from the filesystem
CVE-2025-52543 Login to the application services using only the password hash
CVE-2025-52548 Enabling SSH and Shellinabox on the vulnerable machine
CVE-2025-52545 Privilege escalation in the application services
CVE-2025-52546 Stored XSS by uploading a specially crafted floor plan file
CVE-2025-52549 Predictable root linux password generation

IV. Related Vulnerabilities

V. Comments for CVE-2025-52551

No comments yet


Leave a comment