Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2025-7531— Tenda FH1202 PPTPUserSetting fromPptpUserSetting stack-based overflow

Quick assessment

Affected
Tenda FH1202
Exploitation
Public or AI PoC available; prioritize validation
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda FH1202是中国腾达(Tenda)公司的一款无线路由器。 Tenda FH1202 1.2.0.14(408)版本存在安全漏洞,该漏洞源于文件/goform/PPTPUserSetting中函数fromPptpUserSetting对参数delno的错误操作导致栈缓冲区溢出。

CVSS 8.8 · High EPSS 1.00% · P60
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2025-7531

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda FH1202 PPTPUserSetting fromPptpUserSetting stack-based overflow
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
栈缓冲区溢出
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda FH1202 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda FH1202是中国腾达(Tenda)公司的一款无线路由器。 Tenda FH1202 1.2.0.14(408)版本存在安全漏洞,该漏洞源于文件/goform/PPTPUserSetting中函数fromPptpUserSetting对参数delno的错误操作导致栈缓冲区溢出。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda FH1202 1.2.0.14(408) -

II. Public POCs for CVE-2025-7531

# POC Description Source Link Shenlong Link
AI-Generated POC Premium
Qwen3.6-35B-A3B · 6803 chars
Pro+ exclusive includes:
Vulnerability reproduction recording (real sandbox build + trigger, exclusive)
In-depth vulnerability mechanism
Trigger conditions & impact
Full executable POC code
Exploit chain & mitigation
POC zip download
100+ AI POC generations per month

III. Intelligence Information for CVE-2025-7531

登录查看更多情报信息。

Same Patch Batch · Tenda · 2025-07-13 · 11 CVEs total

CVE-2025-7551 8.8 HIGH Tenda FH1201 PPTPDClient fromPptpUserAdd stack-based overflow
CVE-2025-7550 8.8 HIGH Tenda FH1201 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow
CVE-2025-7549 8.8 HIGH Tenda FH1201 L7Prot frmL7ProtForm stack-based overflow
CVE-2025-7548 8.8 HIGH Tenda FH1201 SafeEmailFilter formSafeEmailFilter stack-based overflow
CVE-2025-7544 8.8 HIGH Tenda AC1206 setMacFilterCfg formSetMacFilterCfg stack-based overflow
CVE-2025-7532 8.8 HIGH Tenda FH1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow
CVE-2025-7530 8.8 HIGH Tenda FH1202 PPTPDClient fromPptpUserAdd stack-based overflow
CVE-2025-7529 8.8 HIGH Tenda FH1202 Natlimit fromNatlimit stack-based overflow
CVE-2025-7528 8.8 HIGH Tenda FH1202 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow
CVE-2025-7527 8.8 HIGH Tenda FH1202 AdvSetWan fromAdvSetWan stack-based overflow

IV. Related Vulnerabilities

V. Comments for CVE-2025-7531

No comments yet


Leave a comment