Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-19924— Tenda AC10 httpd R7WebsSecurityHandler improper authentication

Quick assessment

Affected
Tenda AC10
Exploitation
Public or AI PoC available; prioritize validation
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Tenda AC10是中国Tenda公司的一款无线路由器设备。 Tenda AC10 16.03.10.09_multi_TDE01版本存在授权问题漏洞,该漏洞源于httpd组件中R7WebsSecurityHandler函数存在身份验证不当问题,可能导致远程攻击。

CVSS 9.8 · Critical EPSS 1.42% · P72

Affected Version Matrix 1

VendorProduct Version RangeStatus
Tenda AC10 16.03.10.09_multi_TDE01 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-19924

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda AC10 httpd R7WebsSecurityHandler improper authentication
Source: CVE Program / CVE List V5
Vulnerability Description
A security vulnerability has been detected in Tenda AC10 16.03.10.09_multi_TDE01. This vulnerability affects the function R7WebsSecurityHandler of the component httpd. The manipulation leads to improper authentication. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
认证机制不恰当
Source: CVE Program / CVE List V5
Vulnerability Title
Tenda AC10 授权问题漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda AC10是中国Tenda公司的一款无线路由器设备。 Tenda AC10 16.03.10.09_multi_TDE01版本存在授权问题漏洞,该漏洞源于httpd组件中R7WebsSecurityHandler函数存在身份验证不当问题,可能导致远程攻击。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Tenda AC10 16.03.10.09_multi_TDE01 cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*

II. Public POCs for CVE-2026-19924

# POC Description Source Link Shenlong Link
AI-Generated POC Verified env Premium
Qwen3.6-35B-A3B · 10368 chars
Pro+ exclusive includes:
Vulnerability reproduction recording (real sandbox build + trigger, exclusive)
In-depth vulnerability mechanism
Trigger conditions & impact
Full executable POC code
Exploit chain & mitigation
POC zip download
100+ AI POC generations per month

III. Intelligence Information for CVE-2026-19924

请登录查看更多情报信息。

Security Blog Posts for CVE-2026-19924 (1)

News Coverage for CVE-2026-19924 (1)

Other References for CVE-2026-19924 (2)

IV. Related Vulnerabilities